Options

Example: Initial Cost Comparison

Belt Drive vs. Direct Drive Vari-Green

 

 

GB-121

 

 

 

 

 

 

 

 

G-123-VG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$0

100

200

300

400

500

600

700

 

 

 

Fan Price

 

VFD Price

 

The diagram shows how the overall cost of a fan with a direct drive Vari-Green motor is less than the cost to purchase a belt drive and add a VFD to it.

Vari-GreenControls

Remote mounted dial — wall mounted dial allows fan to be controlled at point of use and includes

a transducer..

Demand Control Ventilation

for multi-story buildings

Applications requiring constant pressure

control or variable volume as used in multi-storied buildings such as hotels, multi-family complexes, institutional

facilities, and high rise commercial buildings, may utilize G fans with Vari-Green™ motor and Vari-Green™ control..

The Vari-Green constant pressure control is preprogrammed and easy to install for applications that include—venting dryers, bathrooms, residential type kitchen space or industrial process exhaust..

Refer to the GreenVent Systems brochure for more detailed information on benefits and energy savings.

Two-speed control — provides the ability to preset a high and low at the fan and control with a timed position switch at the point of use.

Transformer — reduces 115V power to 24V power

Constant pressure — maintains negative pressure (-1.0 wg to = 1.0 wg) for applications such as bathrooms, dryers, filters, etc..

Variable Volume vs. Constant Volume

$2,000-

 

 

 

 

1,750-

 

 

 

 

1,500-

 

 

 

 

1,250-

 

 

 

 

1,000-

 

 

 

 

750-

 

 

 

 

500-

 

 

 

 

250-

 

 

 

 

$-

Variable Volume

Constant Volume

 

Heating Cost ($/yr)

Cooling Cost ($/yr)

Fan Operating Cost

Example

Cost/Savings

Comparisons

Example of potential saving based on a northeast city in the USA using a GreenVent System.

LEED information

Greenheck became one of the first manufacturers in the Air Movement and Control industry to join the LEED/green movement when they joined the United States Green Building Council (USGBC) in 2005.. Greenheck has been actively researching qualification requirements for our products to meet LEED credits and prerequisites..

The Vari-Green™ motor significantly helps qualification efforts for the Energy and Atmosphere credits and

prerequisites — specifically credit one, Optimize Energy Performance and prerequisite two, Minimum Energy Performance.

Demand controlled systems reduce the energy consumed by decreasing the speed of the fan and energy used by the motor.. The system controls will lessen the amount of conditioned air that is exhausted, further reducing the total operating costs..

A 0-10 VDC control signal is easily used in conjunction with:

• BAS - Building Automation System

• GreenVent System Controls - for constant pressure

• CO2 Sensors - Monitors carbon dioxide levels

• VOC Sensors - Monitors a range of volatile organic compounds

• Motion Detectors - Monitors occupancy

For additional information refer to the Vari-Green

Motor brochure.

9

Image 9
Contents Centrifugal Roof Downblast Exhaust Fans Models G and GB Codes and CertificationsModel Comparison Models G and GB Construction FeaturesModel GB Belt Drive Applications Problems after a seismic eventEmergency Smoke Control GB Seismic G and GBHigh Wind and Hurricane G and GB Options Constant Volume Load ShapeVari-GreenMotor Model G HypotheticalDemand Control Ventilation Vari-GreenControlsRoof Curbs Options and AccessoriesSpeed Controllers for Standard Motors Typical Installations General Clean Air figureWheel Rotation GB 240 HP VG/5/A Fan Inlet ConnectionsModel Number Code Roof Downblast Exhaust Direct Drive 060 G-065RPM 070 G-075 080 G-085 090 G-095 GB-071 G-097 Roof Downblast Exhaust Belt & Direct DriveMaximum BHP AT a Given RPM = RPM/33713 Maximum Motor Frame Size =Maximum BHP AT a Given RPM = RPM/29853 GB-081 G-098Maximum BHP AT a Given RPM = RPM/27033 GB-091 G-099Maximum BHP AT a Given RPM = RPM/25933 Maximum RPM = GB-101 G-103Maximum BHP AT a Given RPM = RPM/31653 GB-101HP G-103HPMaximum BHP AT a Given RPM = RPM/21703 Maximum RPM = GB-121 G-123Maximum BHP AT a Given RPM = RPM/20473 GB-131 G-133GB-141 G-143 Maximum BHP AT a Given RPM = RPM/16763Maximum Motor Frame Size = 145T Maximum BHP AT a Given RPM = RPM/23513 GB-141HP G-143HPMaximum BHP AT a Given RPM = RPM/1355 GB-161 G-163Roof Downblast BeltExhaustDrive SizeBelt-Drive GB H-GB GB-161HPMaximum BHP AT a Given RPM = RPM/1708 GB-180 G-183 Maximum BHP AT a Given RPM = RPM/1149Maximum Motor Frame Size = 184T Roof Downblast Exhaust Belt Drive GB-180HPMaximum BHP AT a Given RPM = RPM/1325 Maximum BHP AT a Given RPM = RPM/938 GB-200 G-203Maximum BHP AT a Given RPM = RPM/1106 GB-220HPMaximum BHP AT a Given RPM = RPM/782 GB-220Maximum BHP AT a Given RPM = RPM/838 Maximum BHP AT a Given RPM = RPM/715 GB-240Maximum BHP AT a Given RPM = RPM/845 GB-240HPMaximum BHP AT a Given RPM = RPM/572 GB-260Maximum BHP AT a Given RPM = RPM/517 GB-300Maximum BHP AT a Given RPM = RPM/613 GB-300HPGB-330 Maximum BHP AT a Given RPM = RPM/405Maximum Motor Frame Size = 215T Maximum BHP AT a Given RPM = RPM/394 GB-360Maximum BHP AT a Given RPM = RPM/431 GB-360HPGB-420 Maximum BHP AT a Given RPM = RPM/245 GB-480Maximum Motor Frame Size = 256T GB-500Maximum BHP AT a Given RPM = RPM/202 GB-540Specifications Vari-GreenMotor SpecificationVari-GreenControls Specification Model G Direct Drive SpecificationsHigh Wind Specifications Direct Drive, Severe Duty SpecificationsModel GB Belt Drive SpecificationsSmoke Control Specifications Belt Drive, Severe Duty Specifications097 5-10 101 071-091101HP 5-10 103HP 121 123