Greenheck Fan GB manual Speed Controllers for Standard Motors

Page 11

Options and Accessories

Speed Controllers for Standard Motors

Available for use with shaded pole and permanent split capacitor (PSC) open motors on model G fans.. They provide an economical means of system balancing with direct drive fans.

Coatings

A wide variety of coatings and colors are available. Greenheck coatings and resistance charts can be found in the Performance Coatings Commercial and Industrial Fans catalog and in our Product Application Guide—Performance Coatings for Ventilation Products..

Disconnect Switches

A wide selection of NEMA rated switches are available for positive electrical shutoff and safety, including: dust-tight, rainproof, and corrosion-resistant.. Switches may be internally

or externally mounted..

Dampers

Designed to prevent outside air from entering back into the building when fan is off. Includes gravity and motorized dampers. Damper sizes are shown on each performance data page..

Birdscreen

Galvanized mesh is standard, optional aluminum or stainless steel rigid wire are also available.

G and GB models are Listed for electrical (UL/cUL 705) File no.. E40001

GB models for Emergency Smoke Control Systems (UL/cUL Listed for 500˚F (260˚C) for 4 hours and 1,000˚F (538˚C) for 15 minutes) File no.. MH17511

Note: UL/cUL is optional and must be specified.

PRIMER

PERMATECTORTM

HI-PRO

POLYESTER

Primer is applied at the factory to allow for final finish in the field..

Permatector™ is our standard coating.. Typically used for applications that require corrosion resistance in indoor and outdoor environments..

Hi-Pro Polyester is resistant to salt water, chemical fumes and moisture in more corrosive atmospheres.. Typically used for applications that require superior chemical resistance, excellent abrasion and outdoor UV protection.. This coating exceeds protective qualities of Air Dried Heresite and Air Dry Phenolic..

Baked Enamel Decorative Coatings are heat cured enamels applied either as wet paints or electrostatic powders. Customers can choose from 16 standard decorative colors or color match any color..

11

Image 11
Contents Centrifugal Roof Downblast Exhaust Fans Models G and GB Codes and CertificationsModel Comparison Models G and GB Construction FeaturesModel GB Belt Drive Seismic G and GB Problems after a seismic eventApplications Emergency Smoke Control GBHigh Wind and Hurricane G and GB Hypothetical Constant Volume Load ShapeOptions Vari-GreenMotor Model GDemand Control Ventilation Vari-GreenControlsRoof Curbs Options and AccessoriesSpeed Controllers for Standard Motors Wheel Rotation Typical InstallationsGeneral Clean Air figure Model Number Code GB 240 HP VG/5/AFan Inlet Connections RPM Roof Downblast Exhaust Direct Drive060 G-065 070 G-075 080 G-085 090 G-095 Maximum Motor Frame Size = Roof Downblast Exhaust Belt & Direct DriveGB-071 G-097 Maximum BHP AT a Given RPM = RPM/33713Maximum BHP AT a Given RPM = RPM/29853 GB-081 G-098Maximum BHP AT a Given RPM = RPM/27033 GB-091 G-099Maximum BHP AT a Given RPM = RPM/25933 Maximum RPM = GB-101 G-103Maximum BHP AT a Given RPM = RPM/31653 GB-101HP G-103HPMaximum BHP AT a Given RPM = RPM/21703 Maximum RPM = GB-121 G-123Maximum BHP AT a Given RPM = RPM/20473 GB-131 G-133Maximum Motor Frame Size = 145T GB-141 G-143Maximum BHP AT a Given RPM = RPM/16763 Maximum BHP AT a Given RPM = RPM/23513 GB-141HP G-143HPMaximum BHP AT a Given RPM = RPM/1355 GB-161 G-163Maximum BHP AT a Given RPM = RPM/1708 Roof Downblast BeltExhaustDrive SizeBelt-Drive GB H-GBGB-161HP Maximum Motor Frame Size = 184T GB-180 G-183Maximum BHP AT a Given RPM = RPM/1149 Maximum BHP AT a Given RPM = RPM/1325 Roof Downblast Exhaust Belt DriveGB-180HP Maximum BHP AT a Given RPM = RPM/938 GB-200 G-203Maximum BHP AT a Given RPM = RPM/1106 GB-220HPMaximum BHP AT a Given RPM = RPM/782 GB-220Maximum BHP AT a Given RPM = RPM/838 Maximum BHP AT a Given RPM = RPM/715 GB-240Maximum BHP AT a Given RPM = RPM/845 GB-240HPMaximum BHP AT a Given RPM = RPM/572 GB-260Maximum BHP AT a Given RPM = RPM/517 GB-300Maximum BHP AT a Given RPM = RPM/613 GB-300HPMaximum Motor Frame Size = 215T GB-330Maximum BHP AT a Given RPM = RPM/405 Maximum BHP AT a Given RPM = RPM/394 GB-360Maximum BHP AT a Given RPM = RPM/431 GB-360HPGB-420 Maximum BHP AT a Given RPM = RPM/245 GB-480Maximum Motor Frame Size = 256T GB-500Maximum BHP AT a Given RPM = RPM/202 GB-540Vari-GreenControls Specification SpecificationsVari-GreenMotor Specification Model G Direct Drive SpecificationsHigh Wind Specifications Direct Drive, Severe Duty SpecificationsModel GB Belt Drive SpecificationsSmoke Control Specifications Belt Drive, Severe Duty Specifications123 071-091097 5-10 101 101HP 5-10 103HP 121