Greenheck Fan 470658 MSX manual Adjust the Freeze Temperature

Page 21

NOTE

The Freeze Temperature is preset to the factory recommended 45°F. Steps 9-11 should only be completed if the Freeze Temperature needs adjustment.

NOTE

The Freeze Temperature is the temperature at which the supply solenoid closes and the drain solenoid opens to drain the supply line, preventing possible freeze damage. A drain solenoid is required for this option.

9. Enter Program Mode

Press and hold the Enter Key

for three seconds. The

 

display will read “Pro”

 

when Program Mode is

 

active.

Program Display

 

10. Adjust the Freeze Temperature

While in Program Mode, use the Up and Down

Keys to navigate

 

through the Menu

 

Options until

 

“Frt” is displayed.

 

Press the Enter

 

Key to access the

Freeze Temperature

selected Menu Option

setting.

Display

 

Use the Up and Down Keys to adjust the Freeze Temperature setting as needed. Press the Enter Key to set the Freeze Temperature and return to the Program Menu.

NOTE

The enter key must be pressed to save the new freeze temperature.

11. Exit Program Mode

After 15 seconds of idle time the controller will exit Program Mode.

®

Model MSX Make-Up Air

21

Image 21
Contents General Safety Information Installation, Operation and Maintenance ManualReceiving Inspection and Maintenance during StorageUnpacking HandlingTable of Contents Clearance to Combustibles / Service ClearancesInstallation of Indoor Unit Installation Arrangement DB / HZ / UB Install Curb/Equipment Supports Installation of Roof Mounted Unit Arrangement DBCInstall Combination Extension Install Exhaust FanInstall Supply Unit Locate Equipment Supports Installation of Evaporative Cooling Module optionalSecure Cooling Module to Unit Set Evaporative Cooling ModuleInstallation of Electrical Wiring Sizing of Supply Conductors Installation of Electric Heater optionalInstall the Water Supply Line Installation Evaporative Cooler Piping optionalInstall the Drain Line Check/Adjust Water LevelInstall the Drain Line Install Normally Closed Supply Line/ Solenoid Installation of Water WizardTM optionalInstall Normally Open Drain Line/ Solenoid Wire the SolenoidsInstallation of Direct Expansion DX Coil Piping optional Verify Coil Hand Designation Installation of Chilled Water Coil Piping optionalCheck the Coil for Leaks Connect the Supply and Return LinesMount Pressure Tap Installation of Building Pressure Control optionalRun Pressure Tap Lines Set the Building PressureStart-Up Blower Set-Up Optional Components Air Volume Measurement & CheckSet the Unit’s Operating Temperature Start-Up Electric Heater optionalAirflow Interlock Start-Up Evaporative Cooling Recirculating optional Start-Up Water Wizard optional Adjust the Freeze Temperature Variable Volume Operation Check Operation VAV Units optionalBuilding Pressure Control Building Pressure Control a Exhaust Fan Contact S1 Closed optional Operation ElectricalSupply Fan Contact S2 Closed Electric Heat Contact S4 Closed optionalOperation - Water Wizard optional Blower Does Not Operate TroubleshootingMotor Overamps Too Much Airflow Insufficient AirflowExcessive Noise or Vibration Supply fan must be on for heater to operate Electric Heater Does Not Operate optionalWater Blows through Evaporative Cooler Evaporative Cooler does not Operate Recirculating pumpAdjust the Manual Supply Valve Adjust the On Time FactorWater Wizard Improper Water Supply Belt Drives Maintenance RoutineSnow Accumulation MotorsBearings FiltersEvaporative Coolers Chilled Water Coils Cooling CoilsWinterizing Chilled Water Coils Maintenance FallBlowing-Out Coils Flushing CoilsDirty Filter Switch ReferenceTypical Control Center Layout Start-Up Checklist Start-Up ChecklistStart-Up Evaporative Cooler optional refer Maintenance Log Warranty

470658 MSX specifications

The Greenheck Fan 470658 MSX is a premium performance ventilation solution designed to meet the needs of various commercial and industrial applications. Known for its robustness and efficient air movement capabilities, the MSX series is highly regarded in the industry for its innovative technologies and user-friendly features.

One of the standout features of the Greenheck Fan 470658 MSX is its advanced motor technology. It is equipped with an energy-efficient direct drive motor, which minimizes energy consumption while delivering high airflow rates. The motor's design allows for quieter operation, making it ideal for environments where noise reduction is crucial.

The aerodynamic design of the fan blades is another hallmark of the Greenheck MSX. The blades are engineered to enhance performance by maximizing airflow while reducing turbulence. This design optimization results in increased efficiency and lower operational costs over time. Furthermore, the fan is capable of handling a wide range of air volumes, making it versatile for various installation requirements.

Durability is a key characteristic of the Greenheck Fan 470658 MSX. Constructed from high-quality materials, it can withstand harsh environmental conditions, including exposure to moisture and corrosive elements. The fan housing is designed to be robust, ensuring long-lasting performance and minimal maintenance needs.

In addition to its physical attributes, the MSX series comes equipped with smart technology features. The fan can be integrated with building management systems for real-time monitoring and control, helping facility managers optimize energy usage and maintain indoor air quality. The inclusion of variable speed controls further enhances adaptability, allowing users to adjust fan speed according to specific ventilation needs.

Safety features are also a priority with the Greenheck Fan 470658 MSX. The unit is designed with built-in protections against overheating and overcurrent, ensuring reliable operation under demanding conditions. Additionally, the fan meets rigorous safety standards and certifications, instilling confidence in its performance.

With its combination of efficiency, durability, and innovative features, the Greenheck Fan 470658 MSX is a top choice for those seeking reliable ventilation solutions. Its ability to deliver consistent airflow while minimizing energy consumption sets it apart in the competitive market of industrial fans, making it a valuable investment for businesses looking to enhance their air management systems.