Greenheck Fan 470658 MSX manual Start-Up Checklist, Start-Up Evaporative Cooler optional refer

Page 38

Start-Up Checklist

Start-Up Checklist

Unit Model Number ________________________________

(e.g. MSX-120-H32-DB)

Unit Serial Number ________________________________

 

(e.g. 10111000)

Start-Up Date

________________________________

Start-Up Personnel Name___________________________

Start-Up Company

________________________________

Phone Number

________________________________

Pre Start-Up Checklist check boxes as items are completed.

oCheck tightness of all factory wiring connections

oVerify control wiring wire gauge

oHand-rotate blower to verify free rotation

oVerify supply voltage to the main disconnect

oVerify the supply gas pressure

oVerify remote controls wiring

Start-Up Blower Checklist refer to Blower Start-Up section for further detail.

o Check line voltage

L1-L2___________

 

L2-L3 __________

 

L1-L3___________

oCheck blower rotation

oCheck for vibration

o Supply fan RPM

__________

RPM

o Motor nameplate amps

__________

Amps

o Actual motor amps

__________

Amps

o Actual CFM delivered

__________

CFM

Optional Accessories refer to Blower Start-Up section, Step #6 for further detail.

oHeating Inlet Air Sensor

_________ Actual Setting

Typical setting 60º-70ºF (15º-21ºC)

oCooling Inlet Air Sensor

_________ Actual Setting

Typical setting 75ºF (24ºC

oBuilding Freeze Protection

_________ Actual Setting

Typical setting 5 minutes; 45ºF (7ºC)

oDirty Filter Gauge

_________ Actual Setting Typical setting varies

Start-Up Electric Heater (optional) refer to Electric Heater Start-Up section for further detail.

o Check line voltage

L1-L2___________

 

L2-L3 __________

 

L1-L3___________

oSet the unit’s operating temperature

_________ °F

Start-Up Evaporative Cooler (optional) refer

to Evaporative Cooler Start-Up section for further detail.

oCheck media orientation

oCheck for proper water flow to distribution headers

oCheck for distribution header orientation to prevent water spillage

38

Model MSX Make-Up Air

®

Image 38
Contents Installation, Operation and Maintenance Manual General Safety InformationUnpacking Inspection and Maintenance during StorageReceiving HandlingInstallation of Indoor Unit Table of ContentsClearance to Combustibles / Service Clearances Installation Arrangement DB / HZ / UB Install Combination Extension Installation of Roof Mounted Unit Arrangement DBCInstall Curb/Equipment Supports Install Exhaust FanInstall Supply Unit Secure Cooling Module to Unit Installation of Evaporative Cooling Module optionalLocate Equipment Supports Set Evaporative Cooling ModuleInstallation of Electrical Wiring Installation of Electric Heater optional Sizing of Supply ConductorsInstall the Drain Line Installation Evaporative Cooler Piping optionalInstall the Water Supply Line Check/Adjust Water LevelInstall the Drain Line Install Normally Open Drain Line/ Solenoid Installation of Water WizardTM optionalInstall Normally Closed Supply Line/ Solenoid Wire the SolenoidsInstallation of Direct Expansion DX Coil Piping optional Check the Coil for Leaks Installation of Chilled Water Coil Piping optionalVerify Coil Hand Designation Connect the Supply and Return LinesRun Pressure Tap Lines Installation of Building Pressure Control optionalMount Pressure Tap Set the Building PressureStart-Up Blower Air Volume Measurement & Check Set-Up Optional ComponentsAirflow Interlock Set the Unit’s Operating TemperatureStart-Up Electric Heater optional Start-Up Evaporative Cooling Recirculating optional Start-Up Water Wizard optional Adjust the Freeze Temperature Building Pressure Control Variable Volume OperationCheck Operation VAV Units optional Building Pressure Control a Supply Fan Contact S2 Closed Operation ElectricalExhaust Fan Contact S1 Closed optional Electric Heat Contact S4 Closed optionalOperation - Water Wizard optional Troubleshooting Blower Does Not OperateMotor Overamps Insufficient Airflow Too Much AirflowExcessive Noise or Vibration Electric Heater Does Not Operate optional Supply fan must be on for heater to operateEvaporative Cooler does not Operate Recirculating pump Water Blows through Evaporative CoolerWater Wizard Improper Water Supply Adjust the Manual Supply ValveAdjust the On Time Factor Snow Accumulation Maintenance RoutineBelt Drives MotorsEvaporative Coolers BearingsFilters Cooling Coils Chilled Water CoilsBlowing-Out Coils Maintenance FallWinterizing Chilled Water Coils Flushing CoilsTypical Control Center Layout Dirty Filter SwitchReference Start-Up Evaporative Cooler optional refer Start-Up ChecklistStart-Up Checklist Maintenance Log Warranty

470658 MSX specifications

The Greenheck Fan 470658 MSX is a premium performance ventilation solution designed to meet the needs of various commercial and industrial applications. Known for its robustness and efficient air movement capabilities, the MSX series is highly regarded in the industry for its innovative technologies and user-friendly features.

One of the standout features of the Greenheck Fan 470658 MSX is its advanced motor technology. It is equipped with an energy-efficient direct drive motor, which minimizes energy consumption while delivering high airflow rates. The motor's design allows for quieter operation, making it ideal for environments where noise reduction is crucial.

The aerodynamic design of the fan blades is another hallmark of the Greenheck MSX. The blades are engineered to enhance performance by maximizing airflow while reducing turbulence. This design optimization results in increased efficiency and lower operational costs over time. Furthermore, the fan is capable of handling a wide range of air volumes, making it versatile for various installation requirements.

Durability is a key characteristic of the Greenheck Fan 470658 MSX. Constructed from high-quality materials, it can withstand harsh environmental conditions, including exposure to moisture and corrosive elements. The fan housing is designed to be robust, ensuring long-lasting performance and minimal maintenance needs.

In addition to its physical attributes, the MSX series comes equipped with smart technology features. The fan can be integrated with building management systems for real-time monitoring and control, helping facility managers optimize energy usage and maintain indoor air quality. The inclusion of variable speed controls further enhances adaptability, allowing users to adjust fan speed according to specific ventilation needs.

Safety features are also a priority with the Greenheck Fan 470658 MSX. The unit is designed with built-in protections against overheating and overcurrent, ensuring reliable operation under demanding conditions. Additionally, the fan meets rigorous safety standards and certifications, instilling confidence in its performance.

With its combination of efficiency, durability, and innovative features, the Greenheck Fan 470658 MSX is a top choice for those seeking reliable ventilation solutions. Its ability to deliver consistent airflow while minimizing energy consumption sets it apart in the competitive market of industrial fans, making it a valuable investment for businesses looking to enhance their air management systems.