Cyclic and Compact
Special Features and Maintenance
P120 Ice Box
This is designed for
Door Alarms (E169T, E240B, E249T Only)
If the fresh food compartment door is left open the alarm will beep after 90 seconds.
If the door remains open, subsequent beeps will sound every 30 seconds for 5 minutes. A continuous alarm will sound if the door has been left open for 5 minutes or longer. The alarm will stop when the door is closed.
Fault Alarms
If the electronic controller detects a fault from which it is unable to recover, an alarm will sound when the door is opened.
When the fresh food compartment door is opened and a fault has occurred, a specific number of beeps will sound. If a fault occurs, call your Fisher & Paykel Authorised Service Centre immediately; the number of beeps will help the service person find and remedy the cause of failure.
Humidity Control Cover (635mm Wide Models)
The vegetable bins feature a unique cover which provides two functions:
The humidity control cover seals the bins to provide a humid microclimate to extend storage times. The humidity control cover prevents condensation which forms at high humidities from dripping down onto the fruit and vegetables.
The ability to retain high humidity in the fruit and vegetable bin may produce small amounts of water in the bottom of the fruit and vegetable bin. This can be wiped out as required.
Replacement of Interior Light
Turn the power off at the wall before replacing the lamp. The interior lamp is located at the back of the temperature control box and is removed by unscrewing it.
Replace bulb, making sure it is tightly screwed in. Switch power back on again.
The replacement bulb must not exceed 230 Volt/15 Watt. Bulbs are available from your Fisher & Paykel Authorised Service Centre.
4
1
Unscrew bulb from rear of control box
Important Note: Your refrigerator is designed to operate for many years without the need for frequent service checks. However, if your refrigerator is malfunctioning, have it attended to by your Fisher & Paykel Authorised Service Centre as soon as possible.
All electrical repairs must be carried out by an adequately trained service technician or qualified electrican.