Fisher & Paykel OR90, OR60 Installation instructions, Dimensions and clearances

Page 8

OR60 MODELS

6Installation instructions

Dimensions and clearances

Installation clearances and protection of combustible surfaces shall comply with the current local regulations eg. AG 601 (AS5601/NZS5261) Gas Installations code. Installation shall comply with the dimensions in Fig. 1, bearing in mind the following requirements:

Overhead Clearances

In no case shall the clearance above the highest part of the cooker be less than 600 mm or, for an overhead exhaust fan, 750 mm. AII other downward-facing combustible surfaces less than 600 mm above the cooker surface shall be protected for the full width of the cooking surface in accordance with the standards noted above. In no case shall the clearance be less than 450 mm.

Rear and Side Clearances

Where the distance from the periphery of the nearest burner to any vertical combustible surface is less than 200 mm, the surface shall be protected in accordance with the standards to a height of not less than 150 mm above the cooking surface for the full width or depth of the cooking surface.

Where the distance from the periphery of the nearest burner to any horizontal combustible surface is less than 200 mm, the horizontal surface shall be more than 10 mm below the surface of the cooking surface, or the horizontal surface shall be above the trivet (see requirements for vertical combustible surfaces above).

Protection of combustible surfaces

The standards above specify that, where required, protection shall ensure that the surface temperature of combustible surfaces does not exceed 65°C above room temperature.

Do not install the cooker near flammable materials (eg curtains).

If you stand the cooker on a pedestal, make sure you provide safety measures to keep it in place.

750 mm

 

 

 

 

450 mm

 

 

 

 

 

 

 

 

 

500

mm

 

105

mm

 

Fig. 1 Dimensions and distances from cooker

Cooker overall dimensions [mm]

 

height:

min 900 - max 915

 

product width:

598

 

 

depth:

600

 

cavity width

600

 

 

 

 

 

 

 

 

Image 8
Contents Installation instructions and User guide Page Contents Safety and warnings Installation Power supply Operation Important safety precautions Installation instructions Dimensions and clearancesLevelling the cooker Fitting the anti-tilt bracket Fitting the anti-tilt bracketConnecting the cooker to the gas supply Installation with a flexible hose assemblyLeak-testing and flame-testing the cooker Important! Do not use a naked flame to test for leaksConverting to a different gas type Replacing the injectorsAdjusting the minimum burner setting Table for the choice of injectorsWiring diagram Product width Depth 600 Cavity width 900 Fitting the adjustable feet Area for gas and electrical connectionsMoving the cooker Fixing the backguardPivoting Gas pressure CapCap Auxiliary, rapid and semi-rapid burners Adjusting the minimum burner setting Wiring diagram Page Using your oven Control panel OR60 modelsFunction and temperature knobs Cooking functions BakeUsing your gas cooktop Gas burnersBefore using your cooktop Using the gas burnersIf a burner does not light If the flame is irregularMatching cookware to burner Diameters of pans which may be used on the cooktopSmall pan support Wok standCooktop troubleshooting ProblemCare and cleaning General adviceCleaning the outside of the cooker Cleaning the gas cooktopBurner parts and trivets Replacing the burnersReplacing the triple-ring wok burner Correct positioning of cap and ring triple-ring wok burnerCleaning the inside of your oven Removing the side racksCleaning the oven door glass Cleaning the grill tray and oven floor OR90 modelsDrawer OR60 models Storage compartment OR90 modelsRemoving the oven door Replacing the oven lamp Removing the oven lamp OR60 modelsProduct details Warranty and serviceBefore you call for service or assistance Page Part No a Italy Part No -ß1