Fisher & Paykel DishDrawer manual Operating Installation, Enclosure panels are properly in place

Page 27

i m p o r t a n t s a f e t y i n f o r m a t i o n - s a v e t h e s e i n s t r u c t i o n s

WARNING

When using your , follow basic precautions, including the following: Please read all instructions before

operating the .

Installation

This must be installed and located in accordance with the Installation Instructions before it is used. If you did not receive Installation

Connect to a properly rated, protected and sized power supply circuit to avoid electrical overload.

For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life.

Use the only for its intended function as described in this User Guide.

Use only detergents or rinse agent recommended for use in a domestic dishwasher and keep them out of reach of children. Check that the detergent dispenser is empty after the completion of each wash program.

When loading items to be washed locate sharp items so that they are not likely to damage the lid seal and load sharp knives with the handles up to reduce the risk of cut type injuries.

Do not touch the heater plate during or immediately after use.

Do not operate your unless all the

enclosure panels are properly in place.

Do not tamper with the controls.

Do not abuse, sit on, stand in or on the drawer or dish rack of the .

The cup racks are designed to support cups, glasses and kitchen utensils. When the cup racks are in the do not lean on or use the cup racks to support your body weight.

To reduce the risk of injury, do not allow children to play in or

on the .

Under certain conditions hydrogen gas may be produced in a hot water heater system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period, before using the dishwasher, turn on all hot water taps and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. As gas is flammable, do not smoke or use an open flame during this time.

Remove the door to the washing compartment when removing an old dishwasher from service or discarding it.

Dishwasher detergents are alkaline. They can be dangerous if swallowed. Avoid contact with skin and eyes, keep children and infirm person(s) away from the dishwasher when the drawer is opened.

Instruction sheets with your

, you can order them by calling your

Fisher & Paykel Authorized Service Agent or our Customer Care Center.

Installation and service must be performed by a qualified technician.

If the power supply cord is damaged, it must be replaced by a Fisher & Paykel Dealer or Authorized Service Center or a similar qualified trades person in order to avoid a hazard.

Ensure the is secured to adjacent cabinetry using the brackets provided. Failure to do so may result in an unstable product, which may cause damage or injury.

Do not operate this appliance if it is damaged, malfunctioning, partially disassembled or has missing or broken parts, including a damaged power supply cord or plug.

Do not store or use petrol, or other flammable vapours and liquids in the vicinity of the .

Make sure that the power supply cord is located so that it will not be stepped on, tripped over or otherwise subject to damage or stress.

Do not install or store the where it will be

exposed to temperatures below freezing or exposed to weather.

Do not use an extension cord or a portable electrical outlet device (e.g. multi socket outlet box) to connect the

to the power supply.

25

Image 27
Contents E R G U I D E N t e n t s E r g u i d e PrefinishedT r o d u c t i o n E c i a l t a l e n t s E r a t i n g i n s t r u c t i o n s prefinished model Finish CheckStart PauseLast program used E r a t i n g i n s t r u c t i o n s integrated modelTo select Desired wash.Delay Start Mode optional Cutlery Basket C e s s o r i e sBasket Plate InsertA d i n g HOW to Load YourPersons away from When T e r g e n t d i s p e n s e rFilling the Detergent Dispenser Detergent QuantitiesRinse Agent Indicator Light Hard Water Situations N s e a g e n t d i s p e n s e rSoft Water Situations Above 625ppm, the performance of your will decline Setting Grains per Gallon gpg Parts per Million ppmTo Ensure Optimum Performance of the Water Softener 100 250 350 450 550Open How to Fill the Salt ReservoirSalt Indicator Light Salt ReservoirR i n g f o r y o u r d i n n e r w a r e S h p r o g r a m s Heavy Normal Fast Delicate RinseHeavy Normal Fast Delicate S h w a s h e r s t a n d a r d s t e s t Release the Lock and ECO buttons Enter the Option Adjustment Mode as explained previouslyT i o n a d j u s t m e n t m o d e Prefinished and Integrated ModelsHow to Remove the Auto Power Option How to Install the Closed Drawer Option White or Black Finish CleaningE r m a i n t e n a n c e i n s t r u c t i o n s Iridium Finish Matt Stainless SteelReplace the spray arm back onto the impeller Cleaning the Drain Filter, Spray Arm and Filter PlateLift and remove the drain filter Out Ensure the drain filter is flush with the filter plateTroubleshooting Run Through a wash program Incorrectly placed Correct placementService Agent Will not open May stain the insideFault codes How to Recognize a Fault CodeHow to Attend to a Fault Code Enclosure panels are properly in place Operating InstallationDo not install or store the where it will be To the power supplySupply to the off MaintenanceOperational Damage toCorrecting faults caused by the user This warranty does not coverBefore you call for service or assistance S t o m e r c a r eUSA if you need assistance Is square and level Is fastened securely to the cabinetry E c k l i s tUSA Customer Care 1 888 9 FNP USA 1 888 9 367