Thermador PH54 Installing an Integral Blower VTN1030C, Install blower in hood, Blower preparation

Page 10

Installing an Integral Blower VTN1030C

The hood can be installed with a

VTN1030C blower.

Install blower in hood:

1.The blower is attached to the hood using weld studs provided on the mounting plate.

Blower preparation

Shipping brackets

Wire tie

Capacitor

Blower Front View

Figure 12a

1.Remove left and right shipping brackets and discard.

2.Cut wire tie shown in Figure 12a. Locate the wire harness with the Molex 6-pin connector. Route wire harness out rear of blower, as shown in Figure 12b. below.

3.Re-attach wire harnesses to capacitor with new wire tie (supplied) in same location in front.

Add wire tie here

Wire

Harness

Blower Rear View

2.Figure 12c shows the weld studs in location B for horizontal (rear) discharge. Attach four #10- 24 nuts to the weld studs. For vertical discharge, attach nuts to studs at the top of the mounting plate.

Figure 12c

3.Guide the motor mounting plate over the nuts and tighten to secure the blower to the hood.

4.Attach two (2) additional screws as shown in Figure 12d.

Ventilator

Assembly

Additional

Screws

Figure 12b

Figure 12d

4.Attach wire harness with Molex 6-pin connector to housing as shown in Figure 12b with wire tie (supplied).

CAUTION:

Verify that the two (2) additional screws in Figure 12d are installed and properly tightened before continuing.

9

Image 10
Contents Instrucciones DE Instalación Models PH30 PH36 PH42 PH48 PH54Important Safety Instructions Important Safety Instructions Parts Included with your Hood Parts Not Included with your HoodAppliance Installation Vent unit to outside of building, onlyWall Mount Installation Wooden BracketHood Size Assembly and Installation of the Duct Covers Cabinet Installation Centerline Hole Dimensions for Figures 10Hood can be installed with a VTN1030C blower Installing an Integral Blower VTN1030CInstall blower in hood Blower preparationRoute wires here Wire cover Wiring the Hood with a Remote Blower Wiring the Hood with an Integral MotorRemote Blower Installation Instructions DE Sécurité Importantes Instructions DE Sécurité Importantes Pièces comprises avec la hotte Pièces non comprisesInstallation de lappareil Ventiler lappareil vers lextérieur de lédifice seulementInstallation murale Fixation à bois30 po 13 1/16 po 36 po Assemblage et installation des couvercles de conduit Installation de larmoire Dimensions du trou de la ligne centrale pour lesLa hotte peut être installée avec la Soufflerie VTN1030C Installation de la soufflerie intégrée VTN1030CInstaller la soufflerie dans la Hotte Préparation de la soufflerieAcheminer fil ici Couvercle de fil De fil Installation de la soufflerie à distance Câblage de la hotte avec Moteur intégréInstrucciones Importantes DE Seguridad Cuidado Ventile la unidad hacia afuera del edificioPartes Incluidas con su Campana Partes No Incluidas con su CampanaInstalación del Aparato Figura 1a Dirección de descarga 30, 36, 42, 48Instalación con Montaje en Pared Soporte de MaderaTamaño DE Montaje e Instalación de las Cubiertas de Conducto Instalación con Gabinete 29 -1 13 -7 35 -1 16- 7 41- 1 19 -7 47 -1 22 -7 53 -1 25 -7Instalar el soplador en la Campana Instalar un Soplador Integral VTN1030CPreparación del soplador Se puede instalar la campana con un Soplador VTN1030CFigura 12e Cubierta de cable Conectar la campana con un Soplador Remoto Conectar la campana con un Motor integralInstalación del Soplador Remoto Page Page
Related manuals
Manual 36 pages 33.73 Kb

PH30, PH36, PH42, PH48, PH54 specifications

The Thermador PH series, consisting of the PH54, PH48, PH42, PH36, and PH30 models, represents a pinnacle of culinary design and technology in the world of high-end kitchen appliances. These professional-grade refrigerators are crafted to meet the needs of aspiring chefs and home cooks alike, offering unparalleled performance, spaciousness, and advanced features.

One of the standout characteristics of the PH series is its sleek, integrated design. These refrigerators blend seamlessly with kitchen cabinetry, providing a sophisticated aesthetic that enhances any modern kitchen. With a robust construction, Thermador ensures durability and longevity, making these appliances a smart investment for any kitchen space.

Among the innovative technologies featured in the PH series is the Fresh Food Preservation system. This cutting-edge technology utilizes a precise temperature management system, ensuring that food stays fresher for longer. The models also come equipped with a MultiAirFlow system which optimizes air circulation within the refrigerator, maintaining consistent temperatures throughout and preventing hot spots that can spoil food.

The PH54, PH48, PH42, and PH36 models boast expansive storage options, with adjustable shelves and spacious drawers designed for maximum flexibility. The titling glass shelves allow for easy organization and retrieval, while soft-close mechanisms provide an added touch of luxury and convenience. Each unit also includes a dedicated crisper drawer to keep fruits and vegetables fresh and crisp.

Energy efficiency is a key feature in the PH series, with models designed to consume less energy while delivering high performance. This not only helps the environment but also reduces utility bills, making these refrigerators a practical choice for eco-conscious consumers.

Additionally, the intuitive control panel and Smart Home connectivity allow users to monitor and adjust settings remotely. Thermador’s Home Connect technology enables users to access appliance information via a smartphone app, allowing for greater convenience and customization of settings.

In summary, the Thermador PH series — encompassing the PH54, PH48, PH42, PH36, and PH30 models — combines elegant design, innovative technology, and efficient features to create some of the most sought-after refrigeration solutions on the market. With their focus on quality, performance, and usability, these refrigerators are perfect for anyone looking to elevate their culinary experience.