Thermador PH30, PH54, PH48, PH42 Cabinet Installation, Centerline Hole Dimensions for Figures 10

Page 9

Cabinet Installation

The hood can be installed under a cabinet by supporting the hood from the top.

Note: The cabinet must be structurally joined to the wall studs to support the weight of this hood.

Figure 10 shows the four (4) screw holes (K) used for mounting the hood to the bottom of the cabinet.

Make sure both knockouts have been removed.

1. In the base of the cabinet drill

1/8" tap holes (See Dimension

A in Figure 10 and in Table).

Screw in four #10 x 1" screws

(provided with hood) leaving 1/4"

exposed).

1-9/16"

{ " -1/16 7

K

L

L

A: Tap Hole Locations

23"

L

K

Note: This figure depicts tap hole and screw hole locations only. See Figure1b, Page 4 for overall hood dimensions.

2.

If the hood is installed for

 

vertical discharge, use Figure 11

 

to create clearance holes for

 

passage of the transition and

 

conduit (See Dimension B in

 

Figure 11 and in Table).

3.

For horizontal discharge use

 

Figure 5 for the geometry of the

 

cutout required for clearance of

 

the transition.

4.

Hang hood from screws and

 

tighten securely.

5.

From inside of hood, insert

 

screws supplied. Drill through

 

holes (use #8 x 5/8" screws

 

supplied), one (1) on each side

 

and four along the front, into

Figure 10: Tap Hole and Screw Hole Locations

Centerline Hole Dimensions for Figures 10 and 11

HOOD

A (Fig 10)

B (Fig 11)

SIZE

Tap Holes

Conduit Hole

 

 

 

30"

29-1/16"

13-7/16"

36"

35-1/16"

167/16"

42"

41-1/16"

19-7/16"

48"

47-1/16"

22-7/16"

54"

53-1/16"

25-7/16"

bottom of the cabinet. See

screw holes labeled "L" in

Figure 10.

1 -1/8"

Wall

Cooktop

Centerline

23"

B

2 -3/8"

 

 

 

 

7 7/8"

1- 7/8"

 

 

 

2 3/8"

 

3 -3/16"

5/8" DIA clearance

 

holes for 1/2" conduit

 

 

to j-box.

 

Plan View of Cabinet Cutout

Note: This figure depicts transition and conduit locations only. See Figure 1b, page 4 for overall hood dimensions.

Figure 11: Transition and Conduit Locations

8

Image 9
Contents Models PH30 PH36 PH42 PH48 PH54 Instrucciones DE InstalaciónImportant Safety Instructions Important Safety Instructions Parts Not Included with your Hood Parts Included with your HoodVent unit to outside of building, only Appliance InstallationWooden Bracket Wall Mount InstallationHood Size Assembly and Installation of the Duct Covers Centerline Hole Dimensions for Figures 10 Cabinet InstallationInstall blower in hood Installing an Integral Blower VTN1030CHood can be installed with a VTN1030C blower Blower preparationRoute wires here Wire cover Wiring the Hood with an Integral Motor Wiring the Hood with a Remote BlowerRemote Blower Installation Instructions DE Sécurité Importantes Instructions DE Sécurité Importantes Pièces non comprises Pièces comprises avec la hotteVentiler lappareil vers lextérieur de lédifice seulement Installation de lappareilFixation à bois Installation murale30 po 13 1/16 po 36 po Assemblage et installation des couvercles de conduit Dimensions du trou de la ligne centrale pour les Installation de larmoireInstaller la soufflerie dans la Hotte Installation de la soufflerie intégrée VTN1030CLa hotte peut être installée avec la Soufflerie VTN1030C Préparation de la soufflerieAcheminer fil ici Couvercle de fil De fil Câblage de la hotte avec Moteur intégré Installation de la soufflerie à distanceInstrucciones Importantes DE Seguridad Ventile la unidad hacia afuera del edificio CuidadoPartes No Incluidas con su Campana Partes Incluidas con su CampanaFigura 1a Dirección de descarga 30, 36, 42, 48 Instalación del AparatoSoporte de Madera Instalación con Montaje en ParedTamaño DE Montaje e Instalación de las Cubiertas de Conducto 29 -1 13 -7 35 -1 16- 7 41- 1 19 -7 47 -1 22 -7 53 -1 25 -7 Instalación con GabinetePreparación del soplador Instalar un Soplador Integral VTN1030CInstalar el soplador en la Campana Se puede instalar la campana con un Soplador VTN1030CFigura 12e Cubierta de cable Conectar la campana con un Motor integral Conectar la campana con un Soplador RemotoInstalación del Soplador Remoto Page Page
Related manuals
Manual 36 pages 33.73 Kb

PH30, PH36, PH42, PH48, PH54 specifications

The Thermador PH series, consisting of the PH54, PH48, PH42, PH36, and PH30 models, represents a pinnacle of culinary design and technology in the world of high-end kitchen appliances. These professional-grade refrigerators are crafted to meet the needs of aspiring chefs and home cooks alike, offering unparalleled performance, spaciousness, and advanced features.

One of the standout characteristics of the PH series is its sleek, integrated design. These refrigerators blend seamlessly with kitchen cabinetry, providing a sophisticated aesthetic that enhances any modern kitchen. With a robust construction, Thermador ensures durability and longevity, making these appliances a smart investment for any kitchen space.

Among the innovative technologies featured in the PH series is the Fresh Food Preservation system. This cutting-edge technology utilizes a precise temperature management system, ensuring that food stays fresher for longer. The models also come equipped with a MultiAirFlow system which optimizes air circulation within the refrigerator, maintaining consistent temperatures throughout and preventing hot spots that can spoil food.

The PH54, PH48, PH42, and PH36 models boast expansive storage options, with adjustable shelves and spacious drawers designed for maximum flexibility. The titling glass shelves allow for easy organization and retrieval, while soft-close mechanisms provide an added touch of luxury and convenience. Each unit also includes a dedicated crisper drawer to keep fruits and vegetables fresh and crisp.

Energy efficiency is a key feature in the PH series, with models designed to consume less energy while delivering high performance. This not only helps the environment but also reduces utility bills, making these refrigerators a practical choice for eco-conscious consumers.

Additionally, the intuitive control panel and Smart Home connectivity allow users to monitor and adjust settings remotely. Thermador’s Home Connect technology enables users to access appliance information via a smartphone app, allowing for greater convenience and customization of settings.

In summary, the Thermador PH series — encompassing the PH54, PH48, PH42, PH36, and PH30 models — combines elegant design, innovative technology, and efficient features to create some of the most sought-after refrigeration solutions on the market. With their focus on quality, performance, and usability, these refrigerators are perfect for anyone looking to elevate their culinary experience.