Alto-Shaam EC2-96, EC2-72/P manual EL Ectric AL Conne CT ION, EC2-48 EC2SYS-48 Series

Page 6

EL ECTRIC AL CONNE CT ION

The appliance must be inst alled by a qualified serv ice technician. The oven must be properly grounded in accordance with the Nat ional Elec trical Cod e and applic able loca l codes.

IN STAL LATION

Proper receptacle or outlet config urat ion or permanent wiri ng for this unit must be install ed by a lice nsed electric ian in accordanc e with applic able loc al elect rical cod es.

DAN GER

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in according with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

Plug the unit into a properly grounded recep tac le ONLY, positioning the unit so that the plug is easi ly accessible in case of an emer gency. Arcing will occur when connecting or discon necting the unit unless all controls are in the “OFF” position .

EL ECTR ICAL

EC2-48; EC2SYS-48 SERIES

 

 

 

 

 

VOLTAGE

PHAS E CYCL E/HZ

AMPS

KW

 

120/208-240 (AGENCY)

1

50/60

13.8

3.3

NEMA L14-20P

AT 208

1

50/ 60

11.6

2.5

20A, 250V PLUG

AT 240

1

50/ 60

13.0

3.1

230 (AGENCY)

1

50/60

12.6

2.9

BARE END, NO PLUG

230

1

50/ 60

12.6

2.9

EC2-72; EC2SYS-72 SERIES

 

 

 

 

VOLTAGE

PHAS E CYCL E/HZ

AMPS

KW

 

 

120/208-240 (AGENCY)

1

50/60

18.75

4.5

NEMA L14-30P

AT 208

1

50/ 60

19.0

4.6

AT 240

1

50/ 60

19.0

4.6

30A, 250V

PLUG

230 (AGENCY)

1

50/60

18.3

4.2

BARE END, NO PLUG

230

1

50/ 60

18.4

4.2

EC2-96; EC2SYS-96 SERIES

 

 

 

 

VOLTAGE

PHAS E CYCL E/HZ

AMPS

KW

 

 

120/208-240 (AGENCY)

1

50/60

24.0

5.2

NEM A L14-30P

AT 208

1

50/ 60

24.0

5.2

AT 240

1

50/ 60

24.0

5.2

30A, 250V

PLUG

230 (AGENCY)

1

50/60

24.3

5.6

BARE END, NO PLUG

230

1

50/ 60

24.7

5.7

D AN GER

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

D AN GER

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

REG ARD ING INTERN ATIONAL

STANDARD UNITS:

If the unit is not equi pped with flexible cord with plug, an all-pol e country approve d

disc onnection device which has a contact

sep aration of at least 3mm in all pol es must be incorp ora ted in the fixed wiring for disconnecti on. When using a cord without a plug, the green/yellow conductor shall be conne cted to the terminal which is marked with the grou nd symbol . If a plug is used, the sock et outlet must be easil y acces sib le. If the pow er cord needs replac ement, use a similar one obtained from the dis tributor . For 230V units: To prevent an electrica l sho ck hazard between the applia nce and other

applia nces or metal parts in close vicin ity, an equ aliz ation -bondin g stu d is provide d. An equ aliz ation bonding lead must be con nected to this stud and the other appliances / metal parts to provide suffici ent protect ion against potential diff erence. The terminal is marked with the foll owing symbol .

EC2 & EC2S YS Seri es Oper ati on & Care Manual • 5

Image 6
Contents INS Tallation OperationMainte NAN CE Deli Very Unpack I NGSafety Proc Edures Preca UTI ONS WA RningAU TI on SIT E Inst Allation AU TIO NStal Lation LevelingINS TAL LAT ION SI TE Inst Alla TionEC2 & EC2S YS SE RIE S EL Ectric AL Conne CT ION EC2-48 EC2SYS-48 SeriesEC2 & EC2 SYS Series OP Tion S & ACC ESS Ories User SAF ETY in Forma TIO N Warnin GOpera Ting INS Tructio NS STA RT-U P OPE RAT IONOP ER Ating Instru Ctio NS Operat ING Proced UresPAN CO NFI Guration S H Eate D DI SPL AY C Ases OD ELS 10026 19 1000544 1002585 GEN Eral Hold ING Guid Elines Care and Cleaning CA UtionLeaning and PR Eventi VE MAI Ntenance CAR E AN D Cleanin WA RN in GCA UTI on NI Tation Sanita TIO NServ IC E Coun TE R TOP Front View EC2 -9 6 SH OW NSE Rvice INN ER TOP AS SE MBL Y EC2- 96 ShownCoun TE R TOP BAC K EC 2- 96 SH OWN Lower Rear PanelCoun TE R TOP Bottom EC2 96 SH OWN Coun TE R TOP Well Assembly EC2- 96 SHO WN Coun TE R TOP Well Assembly E C2S YS-9 6 SH OW N DA NG ER EC2 & EC2SY S Seri es Oper at ion & Care Manual EC 2 & EC 2SYS Ser ies Oper ati on & Care Manual EC2 & EC2SY S Seri es Oper at ion & Care Manual EC 2 & EC 2SYS Ser ies Oper ati on & Care Manual EC2 & EC2SY S Seri es Oper at ion & Care Manual EC 2 & EC 2SYS Ser ies Oper ati on & Care Manual EC2 & EC2SY S Seri es Oper at ion & Care Manual EC 2 & EC 2SYS Ser ies Oper ati on & Care Manual EC2 & EC2SY S Seri es Oper at ion & Care Manual Limited Warranty
Related manuals
Manual 2 pages 45.72 Kb

EC2-72/P, EC2-48, EC2-96 specifications

The Alto-Shaam EC2SYS-96 and EC2-96 food holding cabinets are revolutionizing the food service industry with their advanced technology and innovative features. Designed for restaurants, catering services, and food service operations, these commercial-grade cabinets ensure that food is held at optimal temperatures while retaining its quality and flavor.

One of the standout features of the Alto-Shaam EC2SYS-96 and EC2-96 is their patented Halo Heat technology. This technology provides uniform heat distribution with minimal humidity, allowing food to be held at serving temperatures without drying out. Halo Heat is particularly beneficial for delicate items like baked goods, proteins, and vegetables, ensuring they maintain their texture and appearance.

The EC2SYS-96 model boasts a cabinet capacity that can accommodate up to six full-size food pans, ideal for large-scale operations. Its sleek design includes a glass front door, which provides visibility of the food items inside while ensuring energy efficiency. The EC2-96, while similar in capacity, may offer different configurations specifically tailored to unique kitchen workflows.

Both models feature intuitive digital controls that allow for precise temperature adjustments and monitoring. This ensures that food safety standards are constantly met, while also giving chefs the flexibility to tailor the holding environment based on menu requirements. With a temperature range of 60°F to 200°F, operators can hold a variety of foods without fear of overcooking or compromising quality.

Energy efficiency is another crucial characteristic of the EC2SYS-96 and EC2-96. These units are designed to consume minimal energy while providing optimal heat retention, which is a significant consideration for budget-conscious establishments. Their quiet operation further enhances the kitchen environment, making them suitable even for open kitchens or front-of-house applications.

Safety features are integrated into the design, including a ventilated cooling system that prevents overheating and a removable water pan for easy cleaning. The durable construction with stainless steel interiors and exteriors ensures longevity and ease of maintenance.

In summary, the Alto-Shaam EC2SYS-96 and EC2-96 food holding cabinets stand out with their innovative Halo Heat technology, impressive capacity, energy efficiency, and user-friendly controls. These features collectively contribute to maintaining food quality, enhancing operational efficiency, and ensuring the highest standards in food safety and service. For food service operations seeking reliable and effective holding solutions, these models pose an unparalleled choice.