Amana AOES2430 owner manual Grounding Instructions, Wire Electrical System

Page 6

Grounding Instructions

This appliance is manufactured with neutral (white), power supply wire, and a cabinet-connected green (or bare copper) grounding wire.

1.With oven positioned in front of cabinet opening, connect the appliance cable to the junction box through the U.L.-listed conduit connector. Complete electrical connection according to local codes and ordinances. See preferred junction box location in Figure 1 on page 4.

2.Connect wire leads extending through conduit to appropriate supply wires. See following examples.

Where local codes permit connecting the cabinet- grounding conductor to the neutral (white) junction box wire (see Figure 3)

1.Disconnect the power supply.

2.Connect together the 3 wires: bare copper and white appliance cable wires and the neutral (white) wire in the junction box.

3.Connect the 2 black wires together, then the two red wires together.

When connecting to a 4-wire electrical system, when installing in a mobile home, or when local codes DO NOT permit connecting the cabinet- grounding conductor to the neutral (white) junction box wire (see Figure 4)

1.Disconnect the power supply.

2.Separate the bare copper and white wires.

3.Connect the white appliance cable wire to the neutral (white) wire in the junction box.

4.Connect the 2 black wires together, then the two red wires together.

5.Connect the grounding wire (bare copper) to the grounding wire in the junction box.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4 – 4-wire Electrical System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE TO ELECTRICIAN: The armored cable leads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supplied with this appliance are UL-recognized for

 

 

 

 

 

 

 

 

 

connection to larger gauge household wiring. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

insulation of the leads is rated at temperatures much

 

 

 

 

 

 

 

 

 

 

 

 

 

 

higher than the temperature rating of household wiring.

 

 

 

 

 

 

 

 

 

The current carrying capacity of the conductor is

 

 

 

 

 

 

 

 

 

 

 

governed by the temperature rating of the insulation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

around the wire, rather than the wire gauge alone.

Figure 3 –Grounded Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Image 6
Contents Please Read Manual Before Operating Oven Installer CustomerContents All Appliances Important Safety InformationRecognize this symbol as a safety precaution OvenOven Location and Dimensions Important Safety Information InstallationSelf-Cleaning Case of FireSide by Side Installation Connecting Wiring Electrical Shock HazardElectrical Requirements Wire Electrical System Grounding InstructionsAdjusting Oven Height Cabinet InstallationChecking Operation Control Pad Features Pads DescriptionSpecial Modes To enter Special ModesProgramming Set Minute TimerBefore Setting Oven Controls Set Clock 12 hour clockPreheat BakeTimed Bake Broil Delayed BakeVariable Setting Doneness Rack Position FoodsPrepare Oven for Self-Cleaning Adhere to the following cleaning precautionsSelf-Clean To Stop or Interrupt a Self-Cleaning CycleWhen the Self-Clean Cycle is Completed Delayed Self-Clean Reinstalling Oven Door Hinge Type Removing Oven DoorHinge Type Adjusting Oven Temperature Cleaning Wall Oven PartsChanging Oven Light Surfaces How to Clean Before You Call for Service Oven smokes excessively Self-cleaning cycle doesCleaning cycle is During broilingWarranty First YearPage Page Quick Reference Instructions