INSTALLATION
STEP 2: PREPARE THE VENTING SYSTEM
WARNING
To avoid risk of personal injury, property damage, or fire this microwave oven must be properly vented.
NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9.
You may vent your oven in one of three ways. However, do NOT vent into a wall cavity, an attic, or an unused area.
NOTE: If you choose the rear exhaust method
Wall Venting | Roof Venting |
cabinet
|
| |
| / |
|
oven | 3 1/4"x10" | |
duct |
| |
Wall venting |
|
|
| Figure | 5 |
REMEMBER AS YOU INSTALL THE
VENTING:
•Keep the length of the ductwork and the number of elbows to a minimum to
3u4"xl0" I I I
cab_ | i | roof cap |
duct _
oven:lllll
Roof venting
Figure 6
Room Venting | roof cap |
ventilate your oven efficiently. See examples on next page.
cabinet
6" min. | wall cap |
diameter | |
round duct |
|
• Keep the size of the ductwork the same.
• Do not install two elbows together.
• Use duct tape to seal all joints in the duct system.
ove
•Use caulking gun to seal the exterior wall or roof opening around the cap.
| elbow |
| 3 1/4"to round |
| duct transition |
| 3 1/4"to round |
| ductwork transition |