Installation
3.12.Things to do to have the filter usage time calculated automatically
ASP341 models only
(For products connected to the mains water line and equipped with filter)
1.Plug in the refrigerator. Press A (key lock) button simultaneously to enable the key lock.
A |
2.Then press on the following buttons in turn.
4 | 2 | |
3 | ||
| ||
| 1 |
1.Vacation button
2.Fridge temperature setting button
3.Quick Cool setting button
4.Freezer temperature setting button
When the buttons are pressed in the correct order, Key Lock symbol will turn off, buzzer will sound shortly and Filter Change Warning indicator will turn on. When the Filter Replacement Warning button is pressed on, filter usage times are started to be calculated automatically.
C If the filter usage time is calculated automatically, Filter Change Warning indicator will illuminate continuously in a few seconds after the product is plugged
C in.
C
3.13.Before starting to use the water/ice dispenser
(This feature is optional)
•If the water pressure is below 1 bar then a separate pump may need to be used.
•Water system of the refrigerator must be connected to the cold water line. It must not be connected to hot water line.
•No water may be obtained in the initial start- up of the refrigerator. Because there is air in the system. To discharge air from the system, press dispenser latch for
•During initial use, you will have to wait approximately 12 hours for the water to cool down.
•It will take around
•Water pressure must be between
For this, check that 1 glass of water (100 cc) can be filled in 10 seconds.
•The first 10 glasses of water should not be consumed.
•You must wait approximately 12 hours to obtain ice from the ice dispenser for the first time. If there is not enough ice in the ice container, ice may not be obtained from ice dispenser.