Kuppersbusch USA IKD 1157.1 GE-UL installation instructions Eng

Page 9

Manual ND ISLA UL ing.qxd 6/05/2003 11:50 PÆgina 9

6)Fit the part (A) if the inner tube (not supplied) is Ø150 or (A) + (B) if it is Ø120.

7)Attach the inner tube with a clamp (not supplied) to (A) or (B) as the case may be.

8)Introduce the upper tubecover (A8) into the lower tubecover (A9).

9)Adjust the group lower tubecover (A9) and upper tubecover (A8) to the botton inner body (A7) and to the decorative glass wing (U).

10)Fit the circular entrance of the part (A5) to the top part of the inner tube (not supplied) with a clamp (not supplied).

11)Mount the bottom group to the top, fixed to the ceiling with the screws (A10) (M4 x 12)

to the desired height.

12)Mount the part (A5) with the screws (A4) (M4 x 12) in the rectangle parts of the top inner body (A6).

13)Lift the upper tubecover (A8) up to the desired height and fix it to the top group with the screws (G) (M4 x 12, flat head).

14)Adjust finally the decorative glass part (U), fixing it to the body of the kitchen hood using the screws (V) (M4) provided with the glass.

15)Put the filters into the lateral draught section of the motor making the holes in the filters match up (A11) with the pivots (A12) of the motor carcass.

ENG

FIG.2

9

Image 9
Contents IKD 1157.1 GE-UL ENG Important Safety InstructionsDescription of the apparatus Instructions for use IndexProgramming timer Instructions for use Cleaning and maintenanceCleaning the metal filters Changing lightsProblem Possible cause Solution Accesories supplied 22UL324IS 120 2x20 850 m3/hPag Installation with output ventSET type 1 ENG