Installation witouth output vent, with

active charcoal filters (Optional)

When exterior gas extraction to the outside is not possible, then the kitchen hood may be set to purify the air by recycling it through active charcoal filters.

The active charcoal filters have an active life of between three to six months, depending on the individual conditions of use. These filters cannot be washed nor regenerated. They must be replaced once their useful life comes to an end.

SET type 1 - Fig. 2 (Page 9)

1)Using the support (O), trace and drill the points for fitting the lock screws (S) (Ø8 x 45) onto the ceiling.

2)Screw the support (O) into the ceiling with the tirafondos-anclaje (S) (Ø8 x 45).

3)Mount the top inner body (A6) in the support (O) with the screws (Q) (M6 x 16).

4)Softly attach the decorative handle (W) to the decorative glass part (U) with the screws

(X) (M5) and the washer (Y) provided with the glass.

5)Adjust the decorative glass part (U), carrefully fixing it to the body of the kitchen hood using the screws (V) (M4) provided with the glass.

8

Image 8
Contents IKD 1157.1 GE-UL Important Safety Instructions ENGIndex Description of the apparatus Instructions for useInstructions for use Cleaning and maintenance Programming timerCleaning the metal filters Changing lightsProblem Possible cause Solution 22UL324IS 120 2x20 850 m3/h Accesories suppliedInstallation with output vent PagSET type 1 ENG