Part 3 ELECTRICAL CONNECTIONS
4-wire connection: conduit
1. Follow the instructions under “Install the conduit as | ||
follows” on page 7 to correctly install the strain |
|
|
relief. |
|
|
DO NOT install the conduit without a strain relief. |
|
|
|
|
2. Loosen the 2 lower left and right screws from the terminal block. (Refer to Figure 12.)
Remove the lower 2 center screws.
3. Remove ground strap and discard as shown in Figure 12.
Do not discard any screws.
4. Attach the ground bare wire end to range frame and secure it in place with the ground screw (Refer to figure 12.)
5.Insert the bare wire (white/neutral) end through the center terminal block opening.
6. Insert the two side bare wire ends into the left and the right terminal block opening.
Tighten the 3 screws securely into the terminal block. (approximately 35 - 50
7. Go to page 9.
FIGURE 12
ENGLISH
9