Liebherr HC 20 manual Installation Guidelines

Page 3

INSTALLATION GUIDELINES

Area Requirements

Verify the following:

Floors can support refrigerator’s weight plus approximately 1200 pounds (544 kg) of food weight.

Finished kitchen floor height is level. Refrigerator must be adjusted if the floor heights are not equal to make sure air vents are not obstructed.

Remove anything attached to rear or side walls that can obstruct refrigerator opening.

Cutout dimensions are accurate.

Electrical outlet is in correct location.

Do not install this refrigerator-freezer next to any other refrigerator. Installing this refrigerator-freezer next to any other refrigerator or freezer can cause condensation or cause damage to the appliance.

Electrical Requirement

If codes require a separate grounding circuit to be used, have a qualified electrician install the circuit.

ELECTROCUTION HAZARD

Electrical Grounding Required. This appliance is equipped with a three-prong (grounding) polarized plug for your protection against possible shock hazards.

DO NOT remove the round grounding prong from the plug.

DO NOT use a two-prong grounding adapter.

DO NOT use an extension cord to connect power to the unit.

To protect the refrigerator from possible damage, allow the appliance to stand 1/2 to 1 hour in place before turning the electricity on. This allows the refrigerant and system lubrication to reach equilibrium.

Customer’s Responsibility

A 115 Volt, 60 Hz, 15 Amp fused electrical supply is required. We recommend using a dedicated circuit for this appliance to prevent electrical overload. Follow the National Electrical Code and local codes and ordinances when installing the receptacle.

Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do not have a fuse in the neutral or grounding circuit.

ELECTRICAL SHOCK HAZARD

Electrically ground refrigerator.

Do not use an extension cord.

Failure to follow these instructions could result in fire or electrical shock.

Blocking For Safety

The anti-tip bracket must be installed to prevent the unit from tipping after it is installed. Refer to Blocking For Safety.

Unit Venting

Do not restrict the air flow. Air flow must be provided for the unit to operate.

3

Image 3
Contents For Fully Integrated NoFrost Combined Refrigerator-Freezers Instructions de montagePlease Read and Follow These Instructions Installation Guidelines Unit Dimensions Figure Unit Venting Figure Planning InformationDoor swing clearence Figure = 36 914 mm Cabinet Opening Dimensions FigureFramed Cabinet Figure Panel Dimensions Framed Cabinet Design Figure Frameless Cabinet Figure Panel Dimensions Frameless Cabinet Design Figure Mounting the anti tipping device on concrete floors Blocking for SafetyMounting the anti tipping device in cabinets deeper than Mounting the anti tipping device on wooden floorsWater Connection Safety Instructions and WarningsIcemaker IceMakerConnection to the Water Supply Before mounting the door panels InstallationLeveling the appliance Figure Fasten the appliance in the recessMounting the attachment brackets onto the door panels Figure Mounting the refrigerator door Mounting the freezer drawerScrews Figure Mounting the ventilation grille