Rangemaster RMG2H60SS, RMG2H90SS manual Activated charcoal filter Recirculation version, Lighting

Page 12

Activated charcoal filter (Recirculation version)

The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is swi- tched on.

Alarm signal activation

In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off.

Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.

Restore the connection by pressing and holding T1.

Release the button. All five LEDs are turned on.

Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:

-LED flashes twice - Activated charcoal filter saturation alarm ENABLED.

-LED flashes once - Activated charcoal filter saturation alarm DISABLED.

REPLACING THE ACTIVATED CHARCOAL FILTER

Alarm signal reset

Switch off the lights and extractor motor.

Press button T3 for at least 3 seconds, until the leds start to

flash.

Replacing the Filter

Pull the Comfort Panel to open it.

Remove the metal grease filters

Remove the saturated activated carbon filter by releasing the fixing hooks

Fit the new filter by hooking it into its seating

Replace the metal grease filters.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

• Remove the 2 screws fixing the Lighting support, and pull it out of from the Hood.

• Extract the lamp from the Support.

Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.

Replace the Support, fixing it in place with the two screws re- moved as above.

EN

 

1

 

12

Image 12
Contents RMG2H60SS Index Installation MaintenanceRecommendations and Suggestions USECharacteristics Components Ref. Q.ty Product ComponentsInstallation Wall drilling and bracket fixingMounting the hood body ConnectionsDucted Version AIR Exhaust System Recirculation Version AIR OutletFlue assembly Electrical ConnectionUSE Control PanelMaintenance Cleaning the Comfort PanelsRemote Control Optional Cleaning Metal SELF- Supporting Grease FIL Ters Grease filtersLight Replacement Activated charcoal filter Recirculation versionLighting Replacing the Activated Charcoal FilterPage Page Page 436004188ver1