Sea Frost DC 5000 Venting the Gauge SET, Tapping a can of Refrigerant, Venting the Charge Hose

Page 27

VENTING THE GAUGE SET

To connect the gauges to a charged system if the gauge set has not been purged with refrigerant, attach the service valves to the system and vent the hoses at the manifold body by opening the hand wheels to an open center hose for a few seconds allowing some of the system refrigerant to purge the hoses of air. If the center hose is fitted with a check valve it will not be purged and must be purged with the refrigerant supply before introducing charge.

TAPPING A CAN OF REFRIGERANT

Be sure the can of R-134a is clean and dry. Any contaminants on the top of the can or in the hose will enter the system. Turn the can tap valve counterclockwise to retract the piercing point. Thread the valve body on to the can. Be sure the rubber gasket is seated. Next, screw the valve into the valve body, closing the valve, piercing the can. Opening and closing the valve will now regulate the refrigerant flow from the can.

VENTING THE CHARGE HOSE

To avoid pulling air or other contaminants into the system, it is necessary to vent the air from the hose that is used to carry R-134a to the system. To vent the hose, open the can tap valve with the can upright (vapor) then loosen the center hose fitting at the manifold. After several seconds of venting tighten the hose end fitting.

LIQUID OR VAPOR

Refrigerant is either a vapor or liquid. To supply vapor to a system, keep the refrigerant can in the upright position. To supply liquid to the system, invert the can, valve down. Be sure the can is handled carefully to ensure the correct refrigerant condition is supplied.

CHANGING CANS

Turn off the compressor and close the gauge hand wheel Remove the supply hose with check valve from the can tap. Open the valve on the empty can. Some pressure may be present. Wait until no pressure is observed. Remove the can tap from the can.

27

Image 27
Contents DC 5000 System 134a Start UP Procedure and Periodic Inspection RFD Sight Glass Detail Compressor at onceTable of Contents General Description Suggestions Storage of ICE Cubes MaintenanceICE Making Harvesting Vertical TraysHOW Refrigeration Works CleaningTube Handling Installation ~ Work HabitsFIT RFD Last Installing the DC 5000 Compressor UnitTube Cutting Tube BendingPage Plate Location About the PumpValve Unit V/U Drawing Reconnecting PRE-SWAGED Fittings Running the Lines Swagelok PerformanceLine Connection Plan PlanningPositioning the RFD Helpful ToolsRFD Receiver Filter Drier Mounting the RFDInsulating the Lines Cable Ties To leave a sharp end on the cable tieElectrical System Electrical Junction BOX Thermostat Control Panel LocationWire Sizes Fuses WiringGround Wire Assembly Inspection Check ListRefrigerant Refrigerant Handling and SafetyGeneral Safety this is IMPORTANT. Read this DisclaimerAccess to the System Service Access Ports Procedures for Working with R-134aGauges 134a Service Connecting ValvesDisconnecting Gauges Connecting GaugesLiquid or Vapor Venting the Gauge SETTapping a can of Refrigerant Venting the Charge HoseLeak Checking Commissioning Procedure Evacuation with a Vacuum PumpEvacuation Leak Test NEW System Charging Introducing Initial ChargeIf a Leak is Detected Leak Checking a Charged System About PressuresTo Leak Check with Bubbles To Leak Check with AN Electronic DetectorNEW System Charging Reading the Sight Glass Proper Charge Amount General InformationSpecial Note Troubleshooting Discharging the SystemCorrected Page Toll Free in the United States CANADA, and Caribbean Pressure Charts Pressure Charts Pressure Charts DC 5000 Motor and Water Pump Maintenance LubricationBrushes Leeson Motor March Water Pump DC5000 Wiring DC 5000 Layout DC 5000 Water Circuit Twin Valve Systems only

DC 5000 specifications

The Sea Frost DC 5000 is a cutting-edge refrigeration system designed for marine and offshore applications. Known for its reliability and efficiency, the DC 5000 offers superior cooling solutions that are essential for preserving food and other perishable materials on boats and yachts.

One of the standout features of the Sea Frost DC 5000 is its dual refrigeration capability. The system can operate both as a freezer and a refrigerator, allowing users to tailor their cooling requirements based on their specific needs. This flexibility is particularly advantageous for marine environments where space is limited, and energy efficiency is critical.

The DC 5000 is powered by advanced technology that includes a high-efficiency compressor. This compressor is designed to provide powerful cooling while consuming minimal energy, making it ideal for use in remote locations where power resources may be scarce. Coupled with an innovative digital thermostat, the system allows for precise temperature control, ensuring that food remains at optimal storage conditions.

In terms of build quality, the Sea Frost DC 5000 features robust construction that is resistant to the harsh marine environment. It is engineered with high-grade materials that can withstand exposure to saltwater and humidity, reducing the risk of corrosion and ensuring a long service life. This durability is complemented by a compact design that comfortably fits in various spaces on a vessel without compromising usability.

Furthermore, the Sea Frost DC 5000 incorporates a user-friendly interface, providing sailors and boaters with an easy way to monitor and adjust the cooling settings. The system is designed for low noise operation, allowing for a serene onboard experience without the distraction of excessive sound.

A significant advantage of the Sea Frost technology is its ability to run effectively off both AC and DC power, providing flexibility and adaptability in power source selection. This feature ensures that users can always keep their perishables cool, whether docked at a marina or cruising offshore.

Overall, the Sea Frost DC 5000 stands out as an exemplary refrigeration solution for marine use. Its combination of advanced technology, durability, energy efficiency, and user-friendliness make it an essential component for anyone looking to maintain food quality and safety while at sea.