Sea Frost DC 5000 installation instructions Connecting Gauges, Disconnecting Gauges

Page 26

CONNECTING GAUGES

To connect service gauges to the access service ports, remove the protective sealing caps from the service ports on the DC 5000. Note that the ports are of different sizes. The larger diameter port is the discharge side and the smaller port is the suction side. Pull back the collar on the connecting valve and push it over the appropriate access port.

IMPORTANT: There may be a variation in the interface (depending on the brand of service valve being used) between the connecting valve and the service port core valve.

It is important to open each connecting valve carefully. Do not force the connecting valve or turn it to it's stop. Forcing the connecting valve will bend the service port core valve creating a leak.

Turn the connecting valve clockwise to open. During the service operation these valves are left open. Control of refrigerant and vacuum is by the manifold hand wheels.

TO INSTALL GAUGES ON AN UNCHARGED SYSTEM to be evacuated no purging or venting is needed.

TO INSTALL GAUGES ON A CHARGED SYSTEM, with the system off, attach the connecting valves to the service ports. Proceed to Venting the Gauge Set.

DISCONNECTING GAUGES

Disconnecting the gauge set after running the system may be done by turning off the discharge connecting valve first. Remove the connecting valve and re-cap the access service port. Turn off the refrigerant supply. Be sure the end of the yellow center hose is closed. Both hand wheels on the gauge set may now be opened and the compressor operated to extract the refrigerant from the gauges. When the pressure in both gauges drops to the low side operating pressure turn off the hand wheels and the connecting valve. Turn off the compressor. Remove the remaining connecting valve and re-cap the access service port.

Disconnecting the gauge set on a static system may be done by turning off the connecting valves and disconnecting them from the access service ports. Re-cap the access service ports.

26

Image 26
Contents DC 5000 System 134a Start UP Procedure and Periodic Inspection Compressor at once RFD Sight Glass DetailTable of Contents General Description Suggestions Harvesting Vertical Trays MaintenanceICE Making Storage of ICE CubesCleaning HOW Refrigeration WorksInstallation ~ Work Habits Tube HandlingTube Bending Installing the DC 5000 Compressor UnitTube Cutting FIT RFD LastPage About the Pump Plate LocationValve Unit V/U Drawing Reconnecting PRE-SWAGED Fittings Swagelok Performance Running the LinesHelpful Tools PlanningPositioning the RFD Line Connection PlanInsulating the Lines RFD Receiver Filter DrierMounting the RFD Electrical System Cable TiesTo leave a sharp end on the cable tie Thermostat Control Panel Location Electrical Junction BOXWire Sizes Assembly Inspection Check List WiringGround Wire FusesDisclaimer Refrigerant Handling and SafetyGeneral Safety this is IMPORTANT. Read this RefrigerantProcedures for Working with R-134a Access to the System Service Access Ports134a Service Connecting Valves GaugesConnecting Gauges Disconnecting GaugesVenting the Charge Hose Venting the Gauge SETTapping a can of Refrigerant Liquid or VaporNEW System Charging Introducing Initial Charge Commissioning Procedure Evacuation with a Vacuum PumpEvacuation Leak Test Leak CheckingTo Leak Check with AN Electronic Detector Leak Checking a Charged System About PressuresTo Leak Check with Bubbles If a Leak is DetectedNEW System Charging Reading the Sight Glass Special Note Proper Charge AmountGeneral Information Corrected TroubleshootingDischarging the System Page Toll Free in the United States CANADA, and Caribbean Pressure Charts Pressure Charts Pressure Charts Brushes Leeson Motor DC 5000 Motor and Water Pump MaintenanceLubrication March Water Pump DC5000 Wiring DC 5000 Layout DC 5000 Water Circuit Twin Valve Systems only

DC 5000 specifications

The Sea Frost DC 5000 is a cutting-edge refrigeration system designed for marine and offshore applications. Known for its reliability and efficiency, the DC 5000 offers superior cooling solutions that are essential for preserving food and other perishable materials on boats and yachts.

One of the standout features of the Sea Frost DC 5000 is its dual refrigeration capability. The system can operate both as a freezer and a refrigerator, allowing users to tailor their cooling requirements based on their specific needs. This flexibility is particularly advantageous for marine environments where space is limited, and energy efficiency is critical.

The DC 5000 is powered by advanced technology that includes a high-efficiency compressor. This compressor is designed to provide powerful cooling while consuming minimal energy, making it ideal for use in remote locations where power resources may be scarce. Coupled with an innovative digital thermostat, the system allows for precise temperature control, ensuring that food remains at optimal storage conditions.

In terms of build quality, the Sea Frost DC 5000 features robust construction that is resistant to the harsh marine environment. It is engineered with high-grade materials that can withstand exposure to saltwater and humidity, reducing the risk of corrosion and ensuring a long service life. This durability is complemented by a compact design that comfortably fits in various spaces on a vessel without compromising usability.

Furthermore, the Sea Frost DC 5000 incorporates a user-friendly interface, providing sailors and boaters with an easy way to monitor and adjust the cooling settings. The system is designed for low noise operation, allowing for a serene onboard experience without the distraction of excessive sound.

A significant advantage of the Sea Frost technology is its ability to run effectively off both AC and DC power, providing flexibility and adaptability in power source selection. This feature ensures that users can always keep their perishables cool, whether docked at a marina or cruising offshore.

Overall, the Sea Frost DC 5000 stands out as an exemplary refrigeration solution for marine use. Its combination of advanced technology, durability, energy efficiency, and user-friendliness make it an essential component for anyone looking to maintain food quality and safety while at sea.