Sea Frost DC 5000 Leak Checking a Charged System About Pressures, To Leak Check with Bubbles

Page 29

LEAK CHECKING A CHARGED SYSTEM

ABOUT PRESSURES

Refrigerant in a saturated condition, part liquid and part vapor will exert a pressure that is a function of its temperature. The higher the temperature, the higher the pressure. Avoid leak checking in cold weather.

A refrigerant leak will show with moderate pressure. A leak is not a function of pressure. Pressure is only required to aid in detection.

In cold weather, it is possible to raise the pressure in the system by warming the cold plate with a light bulb left in close proximity to the cold plate for several hours with the box lid open.

There are two ways to leak-check a pressurized system:

1.Soap bubbles (a solution of dish soap and water works well).

2.R-134a electronic leak detector (probe senses the presence of refrigerant molecules).

TO LEAK CHECK WITH BUBBLES

Soap each connection and observe all sides of the connection with a bright light and a mirror. A leak will blow bubbles. Without careful examination and plenty of pressure this test is not reliable.

TO LEAK CHECK WITH AN ELECTRONIC DETECTOR

Use a detector designed for R-134a. Slowly trace the area with the probe. Refrigerant is heavier than air, therefore, trace below the fitting. Most units can be calibrated to home in on a leak. We use and recommend electronic detection. TIF brand detectors can accurately detect leaks as low as 1/2 oz. loss per year. This sensitivity exceeds SAE leak specifications. Be sure to test the operation of the detector before and after you leak check the system

IF A LEAK IS DETECTED

If a leak is detected try tightening the fitting nut slightly more. (See Swagelok fittings). If the leak is not stopped, it is possible that the fitting was assembled incorrectly. Discharge the system, and then disconnect the fitting for inspection. After reassembly, proceed to the leak check procedure.

29

Image 29
Contents DC 5000 System 134a Start UP Procedure and Periodic Inspection RFD Sight Glass Detail Compressor at onceTable of Contents General Description Suggestions ICE Making MaintenanceHarvesting Vertical Trays Storage of ICE CubesHOW Refrigeration Works CleaningTube Handling Installation ~ Work HabitsTube Cutting Installing the DC 5000 Compressor UnitTube Bending FIT RFD LastPage Plate Location About the PumpValve Unit V/U Drawing Reconnecting PRE-SWAGED Fittings Running the Lines Swagelok PerformancePositioning the RFD PlanningHelpful Tools Line Connection PlanInsulating the Lines RFD Receiver Filter DrierMounting the RFD Electrical System Cable TiesTo leave a sharp end on the cable tie Electrical Junction BOX Thermostat Control Panel LocationWire Sizes Ground Wire WiringAssembly Inspection Check List FusesGeneral Safety this is IMPORTANT. Read this Refrigerant Handling and SafetyDisclaimer RefrigerantAccess to the System Service Access Ports Procedures for Working with R-134aGauges 134a Service Connecting ValvesDisconnecting Gauges Connecting GaugesTapping a can of Refrigerant Venting the Gauge SETVenting the Charge Hose Liquid or VaporEvacuation Leak Test Commissioning Procedure Evacuation with a Vacuum PumpNEW System Charging Introducing Initial Charge Leak CheckingTo Leak Check with Bubbles Leak Checking a Charged System About PressuresTo Leak Check with AN Electronic Detector If a Leak is DetectedNEW System Charging Reading the Sight Glass Special Note Proper Charge AmountGeneral Information Corrected TroubleshootingDischarging the System Page Toll Free in the United States CANADA, and Caribbean Pressure Charts Pressure Charts Pressure Charts Brushes Leeson Motor DC 5000 Motor and Water Pump MaintenanceLubrication March Water Pump DC5000 Wiring DC 5000 Layout DC 5000 Water Circuit Twin Valve Systems only

DC 5000 specifications

The Sea Frost DC 5000 is a cutting-edge refrigeration system designed for marine and offshore applications. Known for its reliability and efficiency, the DC 5000 offers superior cooling solutions that are essential for preserving food and other perishable materials on boats and yachts.

One of the standout features of the Sea Frost DC 5000 is its dual refrigeration capability. The system can operate both as a freezer and a refrigerator, allowing users to tailor their cooling requirements based on their specific needs. This flexibility is particularly advantageous for marine environments where space is limited, and energy efficiency is critical.

The DC 5000 is powered by advanced technology that includes a high-efficiency compressor. This compressor is designed to provide powerful cooling while consuming minimal energy, making it ideal for use in remote locations where power resources may be scarce. Coupled with an innovative digital thermostat, the system allows for precise temperature control, ensuring that food remains at optimal storage conditions.

In terms of build quality, the Sea Frost DC 5000 features robust construction that is resistant to the harsh marine environment. It is engineered with high-grade materials that can withstand exposure to saltwater and humidity, reducing the risk of corrosion and ensuring a long service life. This durability is complemented by a compact design that comfortably fits in various spaces on a vessel without compromising usability.

Furthermore, the Sea Frost DC 5000 incorporates a user-friendly interface, providing sailors and boaters with an easy way to monitor and adjust the cooling settings. The system is designed for low noise operation, allowing for a serene onboard experience without the distraction of excessive sound.

A significant advantage of the Sea Frost technology is its ability to run effectively off both AC and DC power, providing flexibility and adaptability in power source selection. This feature ensures that users can always keep their perishables cool, whether docked at a marina or cruising offshore.

Overall, the Sea Frost DC 5000 stands out as an exemplary refrigeration solution for marine use. Its combination of advanced technology, durability, energy efficiency, and user-friendliness make it an essential component for anyone looking to maintain food quality and safety while at sea.