Sea Frost DC 5000 installation instructions Tube Cutting, Tube Bending, FIT RFD Last

Page 10

TUBE CUTTING

Use only a tube cutter; hacksawing or any other method will introduce chips to the system and also distort the tube, making connections difficult and leak-prone. A miniature cutter is essential for this work. CUT SLOWLY to avoid a ridge on the inside of the tube. We do not recommend reaming or dressing the cut, as it is very easy to get chips of copper in the system that will cause trouble.

TUBE BENDING

Make all but the long sweep bends with a spring bender; one kink and the line must be rerun. Don't add any more fittings than are absolutely necessary. Route all the lines in such a way that they are most direct but out of the way. Always leave several inches of straight undistorted tubing leading to all Swagelok fittings to allow proper connection.

Again, keep everything sealed until you are ready to make that connection.

FIT RFD LAST

The RFD (receiver, filter, drier) should be the last component to be unpacked and fitted.

INSTALLING THE DC 5000 COMPRESSOR UNIT

Install the DC 5000 in a dry location where the convergence of wires, water hoses and tubing to the refrigerator area are the most convenient. Avoid installing the DC 5000 on

10

Image 10
Contents DC 5000 System 134a Start UP Procedure and Periodic Inspection Compressor at once RFD Sight Glass DetailTable of Contents General Description Suggestions Harvesting Vertical Trays MaintenanceICE Making Storage of ICE CubesCleaning HOW Refrigeration WorksInstallation ~ Work Habits Tube HandlingTube Bending Installing the DC 5000 Compressor UnitTube Cutting FIT RFD LastPage About the Pump Plate LocationValve Unit V/U Drawing Reconnecting PRE-SWAGED Fittings Swagelok Performance Running the LinesHelpful Tools PlanningPositioning the RFD Line Connection PlanMounting the RFD RFD Receiver Filter DrierInsulating the Lines To leave a sharp end on the cable tie Cable TiesElectrical System Thermostat Control Panel Location Electrical Junction BOXWire Sizes Assembly Inspection Check List WiringGround Wire FusesDisclaimer Refrigerant Handling and SafetyGeneral Safety this is IMPORTANT. Read this RefrigerantProcedures for Working with R-134a Access to the System Service Access Ports134a Service Connecting Valves GaugesConnecting Gauges Disconnecting GaugesVenting the Charge Hose Venting the Gauge SETTapping a can of Refrigerant Liquid or VaporNEW System Charging Introducing Initial Charge Commissioning Procedure Evacuation with a Vacuum PumpEvacuation Leak Test Leak CheckingTo Leak Check with AN Electronic Detector Leak Checking a Charged System About PressuresTo Leak Check with Bubbles If a Leak is DetectedNEW System Charging Reading the Sight Glass General Information Proper Charge AmountSpecial Note Discharging the System TroubleshootingCorrected Page Toll Free in the United States CANADA, and Caribbean Pressure Charts Pressure Charts Pressure Charts Lubrication DC 5000 Motor and Water Pump MaintenanceBrushes Leeson Motor March Water Pump DC5000 Wiring DC 5000 Layout DC 5000 Water Circuit Twin Valve Systems only

DC 5000 specifications

The Sea Frost DC 5000 is a cutting-edge refrigeration system designed for marine and offshore applications. Known for its reliability and efficiency, the DC 5000 offers superior cooling solutions that are essential for preserving food and other perishable materials on boats and yachts.

One of the standout features of the Sea Frost DC 5000 is its dual refrigeration capability. The system can operate both as a freezer and a refrigerator, allowing users to tailor their cooling requirements based on their specific needs. This flexibility is particularly advantageous for marine environments where space is limited, and energy efficiency is critical.

The DC 5000 is powered by advanced technology that includes a high-efficiency compressor. This compressor is designed to provide powerful cooling while consuming minimal energy, making it ideal for use in remote locations where power resources may be scarce. Coupled with an innovative digital thermostat, the system allows for precise temperature control, ensuring that food remains at optimal storage conditions.

In terms of build quality, the Sea Frost DC 5000 features robust construction that is resistant to the harsh marine environment. It is engineered with high-grade materials that can withstand exposure to saltwater and humidity, reducing the risk of corrosion and ensuring a long service life. This durability is complemented by a compact design that comfortably fits in various spaces on a vessel without compromising usability.

Furthermore, the Sea Frost DC 5000 incorporates a user-friendly interface, providing sailors and boaters with an easy way to monitor and adjust the cooling settings. The system is designed for low noise operation, allowing for a serene onboard experience without the distraction of excessive sound.

A significant advantage of the Sea Frost technology is its ability to run effectively off both AC and DC power, providing flexibility and adaptability in power source selection. This feature ensures that users can always keep their perishables cool, whether docked at a marina or cruising offshore.

Overall, the Sea Frost DC 5000 stands out as an exemplary refrigeration solution for marine use. Its combination of advanced technology, durability, energy efficiency, and user-friendliness make it an essential component for anyone looking to maintain food quality and safety while at sea.