4-14. Installing Non-PD (Old Style) Wire Guides

1

2

3

4

5

Installing wire guides with non- PD (old- style) drive rolls

.Non-PD (old-style) wire guides and

drive rolls should be used with 5/64 in (2.0 mm) and larger diameter wire.

1PD Inlet Guide

2Intermediate Guide

3Guide Holder

4Exit Guide

5Set Screw

6Pressure Door Assembly

Open pressure door assembly.

Lift up drive roll swing arms.

Install PD inlet guide.

.Do not tighten set screw to secure inlet guide.

.Set screw may be used to secure PD

inlet guide replacements such as wire straighteners or conduit adapters.

Remove screw securing intermediate guide holder. (Guide holder is located between the lower front and rear drive roll carriers.)

6

Ref. 804 732-A

Tools Needed:

1/16, 1/8, 5/32 in

Rotate guide holder 180 degrees and rein- stall.

Install intermediate guide into guide holder and tighten set screw.

Loosen set screw, insert exit guide into block near brass power pin gun connection and secure with set screw.

.When using smaller diameter inlet

guide (219108) with non-PD (old style) drive rolls, a 1/4 in (6 mm) gap will be present between the guide and drive roll.

OM-230 300 Page 17