4-7. Control Box Connections

1

Interconnecting Cables

2

Interconnecting Cable

 

Receptacles

3

14-Pin Cord

1

 

2

 

 

3

 

Ref. 803 187

4-8. 14-Pin Plug Information

 

 

 

Pin*

Pin Information

 

 

 

A

24 volts ac with respect to socket G.

I J

K

A

B

Contact closure to A completes 24 volts ac contactor control circuit.

G

Circuit common for 24 volts ac circuit.

 

 

B

H

N

L C

C

+10 volts dc input from power source to wire feeder with respect to socket D.

G

M

D

D

Remote control circuit common.

F

E

 

 

 

 

 

 

 

E

0 to +10 volts dc output signal from wire feeder to power source with respect to socket D.

 

 

 

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

 

 

 

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.

OM-230 300 Page 13

Page 17
Image 17
Miller Electric DS-75S12, DS-75S16, DS-75D12, and DS-75D16 Control Box Connections, Pin Plug Information, Pin Information