Sea Frost BG 2000 Procedures for Working with R-404a, Access to the System Service Ports

Page 19

PROCEDURES FOR WORKING WITH R-404a

1)A new uncharged system must be evacuated before adding R-404a.

2)An R-404a system must only be pressurized with R-404a or nitrogen.

3)Only service tools dedicated to R-404a are to be used. No parts, tubing, fittings, receivers, dryers, service gauges, or any refrigerant carrying components may be fitted to a R-404a system from a used system or from a CFC based system. Damage caused by the use of parts not supplied by Sea Frost for a R-404a system will cancel all claims against Sea Frost.

4)No oil is to be added to the BG 2000 system but polyolester oil supplied by Sea Frost, labeled and capped for BG 2000 use. No oil is to be added to a system without prior consultation with Sea Frost.

5)The oils used in R-404a systems are moisture sensitive (hydroscopic). Do not leave any tube end or component connection open to air while assembling the system. Be sure to use only new capped copper tubing and be sure to cap the copper coil after cutting it.

ACCESS TO THE SYSTEM: SERVICE PORTS

The service ports are two small capped valves. The low-pressure valve is mounted on the BG 2000 compressor. The high-pressure valve is mounted on a copper tube in the cabinet behind the RFD. (See drawing pg. 33) The ports are standard ¼ inch male flares with core valves. Hose connections must have the proper core depressor insert in it to access the system.

Be sure the caps are installed tightly after charging or service.

NOTE: THIS SYSTEM IS DESIGNED FOR R-404a. IT MUST BE CHARGED WITH R- 404a ONLY. ONLY DEDICATED R-404a GAUGES AND EQUIPMENT ARE TO BE USED. ANY CONTAMINATION FROM CFC BASED REFRIGERANTS WILL DESTROY THIS SYSTEM.

19

Image 19
Contents Operation & Installation Instructions Table of Contents View of the Future Controls BG 2000 OperationDefrosting ICE MakingHarvesting ICE Storage of ICE CubesRoutinely Check BG 2000 MaintenanceCleaning Routine Service and InspectionLAY-UP Winterizing HOW Refrigeration Works Page Tube Bending InstallationTube Handling Tube CuttingPage Step DrawingReconnecting PRE-SWAGED Fittings Mounting Service AccessCondensing Unit Location and Mounting Receiver Filter Drier RFD VisibilityInstalling the Thermostatic Expansion Valve Final Assembly Pump InstallationRunning the Tubing AC Line Circuit Thermostat WiringConnection Access ThermostatRefrigerant Wiring the PumpRefrigerant Handling and Safety General Safety this is IMPORTANT. Read thisAccess to the System Service Ports Procedures for Working with R-404aGauges Disconnecting GaugesVenting the Gauge SET Evacuation Leak Test Commissioning Procedure Evacuation with a Vacuum PumpLeak Checking NEW System Charging Introducing Initial ChargeLeak Checking a Charged System About Pressures Special Note To Check with BubblesTo Check with AN Electronic Detector If a Leak is DetectedReading the Sight Glass Proper Charge Amount RFD Sight Glass DetailGeneral Information Discharging the System Reclaiming Checking the Refrigerant Charge Periodic InspectionHigh Pressure CUTOUT/MANUAL Reset Button TroubleshootingCharge Loss Indicates a Leak That Must be Corrected Call US with ANY Questions BG 2000 Specifications and Operating Characteristics Page Water Circuit Page Page Page Thermostat Calibration Instructions Holdover Plates Stainless Steel Evaporator Plates

BG 2000 specifications

The Sea Frost BG 2000 is a premier refrigeration unit designed to meet the demanding requirements of marine vessels. This advanced cooling system is engineered to provide reliable refrigeration performance even under the most challenging seawater conditions, making it a popular choice among boat owners and commercial fishermen.

One of the main features of the Sea Frost BG 2000 is its innovative evaporator design. The unit employs a unique coil configuration that maximizes surface area for heat exchange, enhancing efficiency and cooling performance. This design ensures that your onboard refrigeration maintains optimal temperatures while consuming less power. This efficiency is crucial for extending the lifespan of gathered produce and maintaining the quality of stored goods.

The BG 2000 utilizes cutting-edge compressor technology, enabling it to deliver superior cooling capacity while minimizing noise and vibration. Its compressor is hermetically sealed, reducing the risk of leakage and ensuring a long operational lifespan. Additionally, the compressor’s variable speed operation allows for tailored cooling performance, adapting to the varying demands of the refrigeration system.

The Sea Frost BG 2000 is engineered for flexibility and ease of installation. Its compact design allows for simple integration into various types of vessels without significant modifications. Furthermore, the unit comes with a user-friendly control panel, giving users the ability to monitor temperatures and adjust settings effortlessly. This ensures that boat owners can maintain optimal refrigeration conditions without the hassle of complicated setups.

Another notable characteristic of the BG 2000 is its robust build. The unit is constructed with corrosion-resistant materials, ensuring durability in the harsh marine environment. This durability extends to its components, which are designed to withstand the rigors of saltwater exposure, ensuring a long service life under demanding conditions.

To further improve its functionality, the Sea Frost BG 2000 incorporates environmentally-friendly refrigerants that comply with modern regulations, promoting sustainability without compromising performance. With an emphasis on energy efficiency, this unit helps reduce fuel consumption, which is a critical consideration for marine operations seeking to lower operational costs.

In summary, the Sea Frost BG 2000 stands out in the marine refrigeration market, boasting advanced features, durable construction, and efficient operation. Its innovative design and technology make it an invaluable asset for any vessel looking to maintain high-quality refrigeration in an eco-friendly manner. Whether for commercial fishing or leisure cruising, the BG 2000 proves to be a reliable and efficient choice for marine refrigeration needs.