Sea Frost installation instructions BG 2000 Specifications and Operating Characteristics

Page 30

BG 2000 Specifications and Operating Characteristics

 

 

 

 

115-volt 50/60 hz

230-volt 50/60 hz

Horsepower

1 HP

1HP

Refrigerant

404-a

404-a

Oil

Polyol ester oil

Polyol ester oil

Locked rotor amps

76.7

45

Current draw with pump

26.8 amps

14.10 amps

Electrical breaker

30 amp

15 amp double

 

 

pole

Maximum refrigerant charge

24 oz

24 oz

Manual reset high pressure cut-out

325 PSIG

325 PSIG

March pump

LC-3

LC-3

Integral low voltage thermostat circuit

24-volt AC

24-volt AC

Pressure trends: Gauge pressure PSIG

 

 

 

 

Water temp 60

Water temp 80

 

degrees F.

degrees F.

Hi Pressure

175

190

Low Pressure (Warm Plates)

30

30

Low pressure (Cold Plates)

7 to 5

7 to 5

 

 

 

Pressures are approximate: High pressure will momentarily rise beyond operating pressure until the expansion valve starts to restrict flow. Condensing pressure will be 15 degrees above water temp.

Low pressure will drop from equalized at start up to settle at the indicated low reading in a period of about 45 minutes depending on the number of plates and starting temperature. Proper thermostat set up should cycle the compressor in this low- pressure range.

THE EXPANSION VALVES HAVE BEEN FACTORY ADJUSTED FOR OPTIMUM PERFORMANCE. DO NOT ADJUST THIS VALVE FOR ANY REASON. INCORRECT SETTINGS MAY RUIN THE COMPRESSOR!

30

Image 30
Contents Operation & Installation Instructions Table of Contents View of the Future BG 2000 Operation ControlsStorage of ICE Cubes ICE MakingHarvesting ICE DefrostingRoutine Service and Inspection BG 2000 MaintenanceCleaning Routinely CheckLAY-UP Winterizing HOW Refrigeration Works Page Tube Cutting InstallationTube Handling Tube BendingPage Drawing StepReconnecting PRE-SWAGED Fittings Receiver Filter Drier RFD Visibility Service AccessCondensing Unit Location and Mounting MountingInstalling the Thermostatic Expansion Valve Pump Installation Final AssemblyRunning the Tubing Thermostat Thermostat WiringConnection Access AC Line CircuitGeneral Safety this is IMPORTANT. Read this Wiring the PumpRefrigerant Handling and Safety RefrigerantProcedures for Working with R-404a Access to the System Service PortsDisconnecting Gauges GaugesVenting the Gauge SET Commissioning Procedure Evacuation with a Vacuum Pump Evacuation Leak TestNEW System Charging Introducing Initial Charge Leak CheckingLeak Checking a Charged System About Pressures If a Leak is Detected To Check with BubblesTo Check with AN Electronic Detector Special NoteReading the Sight Glass RFD Sight Glass Detail Proper Charge AmountGeneral Information Checking the Refrigerant Charge Periodic Inspection Discharging the System ReclaimingTroubleshooting High Pressure CUTOUT/MANUAL Reset ButtonCharge Loss Indicates a Leak That Must be Corrected Call US with ANY Questions BG 2000 Specifications and Operating Characteristics Page Water Circuit Page Page Page Thermostat Calibration Instructions Holdover Plates Stainless Steel Evaporator Plates

BG 2000 specifications

The Sea Frost BG 2000 is a premier refrigeration unit designed to meet the demanding requirements of marine vessels. This advanced cooling system is engineered to provide reliable refrigeration performance even under the most challenging seawater conditions, making it a popular choice among boat owners and commercial fishermen.

One of the main features of the Sea Frost BG 2000 is its innovative evaporator design. The unit employs a unique coil configuration that maximizes surface area for heat exchange, enhancing efficiency and cooling performance. This design ensures that your onboard refrigeration maintains optimal temperatures while consuming less power. This efficiency is crucial for extending the lifespan of gathered produce and maintaining the quality of stored goods.

The BG 2000 utilizes cutting-edge compressor technology, enabling it to deliver superior cooling capacity while minimizing noise and vibration. Its compressor is hermetically sealed, reducing the risk of leakage and ensuring a long operational lifespan. Additionally, the compressor’s variable speed operation allows for tailored cooling performance, adapting to the varying demands of the refrigeration system.

The Sea Frost BG 2000 is engineered for flexibility and ease of installation. Its compact design allows for simple integration into various types of vessels without significant modifications. Furthermore, the unit comes with a user-friendly control panel, giving users the ability to monitor temperatures and adjust settings effortlessly. This ensures that boat owners can maintain optimal refrigeration conditions without the hassle of complicated setups.

Another notable characteristic of the BG 2000 is its robust build. The unit is constructed with corrosion-resistant materials, ensuring durability in the harsh marine environment. This durability extends to its components, which are designed to withstand the rigors of saltwater exposure, ensuring a long service life under demanding conditions.

To further improve its functionality, the Sea Frost BG 2000 incorporates environmentally-friendly refrigerants that comply with modern regulations, promoting sustainability without compromising performance. With an emphasis on energy efficiency, this unit helps reduce fuel consumption, which is a critical consideration for marine operations seeking to lower operational costs.

In summary, the Sea Frost BG 2000 stands out in the marine refrigeration market, boasting advanced features, durable construction, and efficient operation. Its innovative design and technology make it an invaluable asset for any vessel looking to maintain high-quality refrigeration in an eco-friendly manner. Whether for commercial fishing or leisure cruising, the BG 2000 proves to be a reliable and efficient choice for marine refrigeration needs.