The drain outlet is located front and center of the cases for convenient access. The drain outlet on the KRZH is molded out of ABS material. The “P” trap, furnished with the case, is constructed of schedule 40 PVC pipe. Care should be given to assure that all connections are water tight and sealed with the appropriate PVC cement, ABS cement, or pipe dope.

The lines can be run left or right of the tee with the proper pitch to satisfy local drainage requirements.

PLUMBING

The kickplate is shipped loose with the case for field installation, therefore you should have open access to the drain line area. If the kickplate has been installed, you will find it very easy to remove. See instructions below, or the line-up and trim out section of this manual on page 7.

44 5/8 in

[113.3 cm]

19 5/8 in. [49.8 cm.] {2-DOOR}

EXTERNAL PLUMBING

 

 

 

 

 

34 5/8 in. [87.9 cm.] {3-DOOR}

11 7/16 in [29.1 cm]

 

 

49 5/8 in. [126.0 cm.] {4-DOOR}

 

 

2 13/16 in [7.1 cm]

 

 

64 5/8 in. [164.1 cm.] {5-DOOR}

 

 

 

 

 

20 3/4 in

 

 

 

[52.7 cm]

 

39 1/8 in

44 5/8 in

**

 

 

[99.4 cm]

[113.3 cm]

 

 

 

 

42 7/16 in

 

 

[107.8 cm]

 

 

1 1/2 in [3.8 cm]

 

1 1/2" PVC DRAIN

{END}

 

 

CONNECTION

 

 

 

C

 

 

 

L

 

 

FRONT OF CASE

60 in. [152.4 cm.] {2-DOOR}

90 in. [228.6 cm.] {3-DOOR}

120 in. [304.8 cm.] {4-DOOR}

150 in. [381.0 cm.] {5-DOOR}

NOTES:

*STUB-UP AREA

**RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

MODEL

KRZH

HOW TO REMOVE KICKPLATE

LIFT UP FROM “J” RAIL

AND PULL OUT

KICKPLATE

“J” RAIL

9

Image 13
Contents Handbook Page Hill Phoenix Page Table of Contents General Information Model Basehorse Location for Model Krzh Casters Line UP Trim OUT Remove Shipping Accessories From Case. Add Sealant Refrigeration Piping Plumbing Electrical Hookup Anthony Wiring DIAGRAMS- Modelkrzh Wiring DIAGRAMS- Modelkrzh Wiring DIAGRAMS- Modelkrzh Wiring DIAGRAMS- Modelkrzh Wiring DIAGRAMS- Terminalblock Wiring DIAGRAMS- GFI Glass Door Reach-in Frozen Food/Ice Cream Merchandiser Defrost and Temp Control AIR Flowand Product Loading USE and Maintenance Door Parts Ordering Model Krzh Model Krzh Appendix a Warranty Maintenance & Case Care