hussman RHR-SQ, rhr-hex Wiring Diagrams, Loads, amp, 208 240 19.7 22.8 14.2 16.4, W6100012

Page 13

Griddle

(6) 206W/220VAC Flexible Heater Pad #225-01-6770/-6770T

Overhead Lighting

INCANDESCENT LAMPS

GE APPLIANCE BULB PC15206-100A15-CD1-100 WATT- 115V

(6) 125-03-1206 100WATT INCANDESCENT LAMP

(6) 125-01-0287 LIGHT SOCKET

White Red White

White Red White

White Red White

 

Loads, amp

 

208 V

240 V

L1

19.7

22.8

L2

14.2

16.4

L3

0.0

0.0

 

 

 

Note: Case MUST be grounded

Rev. 0608

Overhead Heating Element HE-04-68" #125-01-3235

2700 W / 240 VAC

Ledge Lights-optional

13

White Red White

Bulb Sensor

White Red White

White Red White

Electronic

T-Stat

POWER

 

 

 

P1

 

 

1

2

3

4

5

6

7

#125-01-0311

 

 

 

 

 

 

 

COOLING

FAN

MOTOR

H1

H2

M

P L1 L2

(2) F14T5/TL830

-135

(2) F14T5/TL830

-135

(2) F14T5/TL830

-135

Wiring Diagrams

L1

L2

L

 

Contactor #125-0011001-

 

s

 

 

SAFETY T-STAT

LCLOSE ON RISE NGT # 11S31T4444

Pilot Light225-01-0076 ON: 98.6°F

OFF: 80.6°F

(LOCATED IN COLUMN)

L

Pilot Light

SWITCH

125-01-0311

L

15 AMP

FUSE 125-01-3282

FUSE HOLDER 125-01-3283

L

WH2-120

WH2-120

WH2-120

L3

N

G

~208 / 240V - 1 Ø - 60Hz

SWITCH 125-01-0311

®

HussmannCorporation

Revisions:

 

 

Drawn By:

D.QUAN

Project Title: RHR-Hex-4' basic

Drawing No.:

 

13770 RamonaAvenue

No.

Description:

Date:

By:

Checked By:

 

 

W6100012

 

Chino, CA. 91710

1

DELETED (1) 225-01-3301

08/05/05

D.Q.

Date:

06.12.2000

 

 

(909)-590-4910

 

 

 

 

Drawing Title: RHR Hex 4' Case Wiring

 

 

 

 

 

 

Next Assembly:

final

 

 

Lic.#: 644406

 

 

 

 

Sheet 1 of 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 13
Contents Island hot food case RevGeneral Instructions Table of ContentsCut and Plan Views InstallationRHR-HEX 6 LevelingBumper Installation Instructions Installation ContdHelpful Hints Boston SeriesBoston 2000 Eco Series Boston 1000 Series Installation Field Wiring and Serial Plate Amperage Wiring Color Code Electrical Circuit IdentificationElectrical Ballast LocationUser Information User Information Contd Replacing Overhead Heat Lamps MaintenanceRHR-HEX Electrical Wiring DiagramsLoads, amp Wiring Diagrams208 240 19.7 22.8 14.2 16.4 W6100012DiagramsContd Wiring208 V 240 21.1 23.9 11.3 0608Contd Diagrams19.8 22.2 15.3 17.7 Wiring Diagrams ContdW6100020 HEX-0608W6100015 208 V 240 L1 24.5 L2 18.6 L3 16.1RHR HEX 5-6 1 Shelf Unit W6100005 26.54 Square Case Model 10.2 Wiring DiagramsFlr Lamps, Contactor W610000714.8 17.1 16.5 18.8 10/22/99 Drawing Title RHR Hex 56 1/2 Case Wiring208 / 240 VAC 1Ø 50 / 60z W6100008Appendices Appendix A. Temperature GuidelinesAppendix C. Field Recommendations Appendix D. Recommendations to UserAppendices Contd Service Record
Related manuals
Manual 20 pages 54.64 Kb

RHR 1/2 HEX, RHR2-HEX, RHR-SQ, rhr-hex specifications

The Hussman RHR-HEX is a cutting-edge refrigeration unit designed to meet the demands of modern retailers while focusing on energy efficiency, sustainability, and robust performance. This advanced refrigeration system has garnered attention due to its unique features and technologies that enhance both its functionality and ease of use.

One of the standout features of the RHR-HEX is its compact design which allows for flexibility in store layouts. The unit can be installed in various configurations, making it suitable for diverse retail environments, from supermarkets to convenience stores. Its modular design also simplifies maintenance, enabling quick access to components, which reduces downtime and operational disruptions.

The RHR-HEX employs state-of-the-art cooling technology that utilizes a high-efficiency compressor, which significantly lowers energy consumption. This efficiency is further supported by a smart control system that optimizes performance according to varying load conditions. The advanced thermal insulation used in the unit ensures minimal energy loss, contributing to lower operational costs.

Additionally, the Hussman RHR-HEX incorporates integrated LED lighting which not only enhances product visibility but also consumes less power compared to traditional lighting solutions. This feature aligns with the growing emphasis on sustainability in retail practices, further reducing the carbon footprint of the store.

One of the key characteristics of the RHR-HEX is its ability to operate in high ambient temperatures, making it a reliable choice for warmer climates. Its robust design ensures consistent performance, even under challenging conditions, thus maintaining the integrity of stored products, especially perishables.

Furthermore, the unit supports eco-friendly refrigerants, in line with global environmental standards. By adopting refrigerants with a lower global warming potential, Hussman demonstrates its commitment to sustainable practices that comply with regulations and promote a healthier planet.

In conclusion, the Hussman RHR-HEX is a solution that embodies efficiency, versatility, and sustainability in refrigeration. Its advanced features, combined with innovative technologies, make it an ideal choice for retailers looking to enhance operational efficiency while supporting environmentally friendly practices. With the RHR-HEX, retailers not only achieve their cooling needs but also contribute to a more sustainable future.