hussman RHR2-HEX, rhr-hex, RHR-SQ, RHR 1/2 HEX General Instructions, Table of Contents

Page 2

IGHT-RHR, RHR2-HEX-0608

General Instructions

Table of Contents

 

General Instructions

2

Cut and Plan Views

3

Installation

3

Leveling

3

Bumper Installation Instructions

4

Electrical

8

Wiring Color Code

8

Electrical Circuit Identification

8

Field Wiring and Serial Plate Amperage

8

Ballast Location

8

User Information

9

Food Handling

9

Important Operation Tips:

9

Controls

9

Overhead Heating System

9

Care and Cleaning

9

General Cleaning Rules

9

Cleaning Instructions

10

Plexiglass and Acrylic Care

10

Antistatic Coatings

10

Cleaning Precautions

10

Maintenance

11

Replacing Overhead Heat Lamps

11

Electrical Wiring Diagrams

12

Wiring Diagrams

13

Appendices

21

Appendix A. - Temperature Guidelines

21

Appendix B. - Application Recommendations

21

Appendix C. - Field Recommendations

21

Appendix D. - Recommendations to User

21

This Booklet Contains Information on:

The RHR-HEXis a self-service Hot Food Hexagon-shaped Island Stand, available in 4 and 6 foot sizes.

The RHR2-HEXis a similar unit, with the addition of a second shelf: Both feature surface and overhead food warmers, but both are also available with an overhead Radiant Heat option.

Shipping Damage

All equipment should be thoroughly examined for shipping damage before and during unloading.

This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe arrival. If damaged, either apparent or concealed, claim must be made to the carrier.

Apparent Loss or Damage

If there is an obvious loss or damage, it must be noted on the freight bill or express receipt and signed by the carrier’s agent; otherwise, carrier may refuse claim. The carrier will supply necessary claim forms.

Concealed Loss or Damage

When loss or damage is not apparent until after all equipment is uncrated, a claim for concealed damage is made. Make request in writing to carrier for inspection within 15 days, and retain all packaging. The carrier will supply inspection report and required claim forms.

Shortages

Check your shipment for any possible shortages of material. If a shortage should exist and is found to be the responsibility of Hussmann Chino, notify Hussmann Chino. If such a shortage involves the carrier, notify the carrier immediately, and request an inspection. Hussmann Chino will acknowledge shortages within ten days from receipt of equipment.

Hussmann Chino Product Control

The serial number and shipping date of all equipment has been recorded in Hussmann’s files for warranty and replacement part purposes. All correspondence pertaining to warranty or parts ordering must include the serial number of each piece of equipment involved, in order to provide the customer with the correct parts.

Keep this booklet with the case at all times for future reference.

/CHINO

A publication of HUSSMANN® Chino

13770 Ramona Avenue • Chino, California 91710

(909)628-8942 FAX

(909)590-4910

(800)395-9229

This equipment is to be installed to comply with the applicable NEC, Federal, State,and Local Plumbing and Construction Code ha ving jurisdiction.

Image 2
Contents Rev Island hot food caseTable of Contents General InstructionsRHR-HEX 6 InstallationCut and Plan Views LevelingInstallation Contd Bumper Installation InstructionsBoston Series Helpful HintsBoston 2000 Eco Series Boston 1000 Series Installation Electrical Wiring Color Code Electrical Circuit IdentificationField Wiring and Serial Plate Amperage Ballast LocationUser Information User Information Contd Maintenance Replacing Overhead Heat LampsElectrical Wiring Diagrams RHR-HEX208 240 19.7 22.8 14.2 16.4 Wiring DiagramsLoads, amp W6100012208 V 240 21.1 23.9 11.3 WiringDiagramsContd 0608Diagrams ContdW6100020 Wiring Diagrams Contd19.8 22.2 15.3 17.7 HEX-0608RHR HEX 5-6 1 Shelf Unit 208 V 240 L1 24.5 L2 18.6 L3 16.1W6100015 4 Square Case Model 26.5W6100005 Flr Lamps, Contactor Wiring Diagrams10.2 W6100007208 / 240 VAC 1Ø 50 / 60z 10/22/99 Drawing Title RHR Hex 56 1/2 Case Wiring14.8 17.1 16.5 18.8 W6100008Appendix C. Field Recommendations Appendix A. Temperature GuidelinesAppendices Appendix D. Recommendations to UserAppendices Contd Service Record
Related manuals
Manual 20 pages 54.64 Kb

RHR 1/2 HEX, RHR2-HEX, RHR-SQ, rhr-hex specifications

The Hussman RHR-HEX is a cutting-edge refrigeration unit designed to meet the demands of modern retailers while focusing on energy efficiency, sustainability, and robust performance. This advanced refrigeration system has garnered attention due to its unique features and technologies that enhance both its functionality and ease of use.

One of the standout features of the RHR-HEX is its compact design which allows for flexibility in store layouts. The unit can be installed in various configurations, making it suitable for diverse retail environments, from supermarkets to convenience stores. Its modular design also simplifies maintenance, enabling quick access to components, which reduces downtime and operational disruptions.

The RHR-HEX employs state-of-the-art cooling technology that utilizes a high-efficiency compressor, which significantly lowers energy consumption. This efficiency is further supported by a smart control system that optimizes performance according to varying load conditions. The advanced thermal insulation used in the unit ensures minimal energy loss, contributing to lower operational costs.

Additionally, the Hussman RHR-HEX incorporates integrated LED lighting which not only enhances product visibility but also consumes less power compared to traditional lighting solutions. This feature aligns with the growing emphasis on sustainability in retail practices, further reducing the carbon footprint of the store.

One of the key characteristics of the RHR-HEX is its ability to operate in high ambient temperatures, making it a reliable choice for warmer climates. Its robust design ensures consistent performance, even under challenging conditions, thus maintaining the integrity of stored products, especially perishables.

Furthermore, the unit supports eco-friendly refrigerants, in line with global environmental standards. By adopting refrigerants with a lower global warming potential, Hussman demonstrates its commitment to sustainable practices that comply with regulations and promote a healthier planet.

In conclusion, the Hussman RHR-HEX is a solution that embodies efficiency, versatility, and sustainability in refrigeration. Its advanced features, combined with innovative technologies, make it an ideal choice for retailers looking to enhance operational efficiency while supporting environmentally friendly practices. With the RHR-HEX, retailers not only achieve their cooling needs but also contribute to a more sustainable future.