Installation
Technical Data |
| Heating elements rating |
|
|
Dimensions of recess |
| Fan Oven | 2,000 | W |
|
|
|
| |
Height | 580 mm | Grill element | 1,650 | W |
|
|
| ||
Width | 560 mm | Convection Fan | 25 W | |
Depth | 550 mm | Oven Light | 25 W | |
|
| Cooling Fan | 25 W | |
Dimensions of the oven cavity |
| Total Rating | 2,050 | W |
Height | 335 mm | Supply voltage (50 Hz) | 230 V | |
Width | 395 mm |
|
|
|
Depth | 400 mm |
|
|
|
Oven capacity | 53 litres |
|
|
|
Electrical Connection
THIS OVEN MUST BE EARTHED
Electrical Requirements
Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician, e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz) electricity supply.
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate on the side of the oven door.
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal |
Letter N | - | Neutral terminal |
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
It is necessary that the yellow/green earth wire is about 2 cm longer than the live and neutral ones.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
or E | - | Earth terminal |
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.
For UK use only
Connection | Min. size | Cable / flex | Fuse |
via | Cable/flex | type |
|
|
|
|
|
• Cooker | 2.5 mm2 | PVC/PVC | 20 A |
Control |
| twin and |
|
Circuit |
| earth |
|
|
|
|
|
For Europe use | only |
| |
|
|
|
|
Min. size Cable/flex |
| Cable / flex type | Fuse |
|
|
|
|
2.5 mm2 |
| H07 | 15 A |
|
| H05 |
|
|
| H05 |
|
|
| H05 |
|
|
|
|
|
5