hussman IGHT-ESH/ESHS-0010 manual IndividualWellsHotFoodSelf-ServiceCounters, 50/60

Page 39

Rev. 0010

F28T5/TL830 (2)

F28T5/TL830 (2)

F28T5/TL830 (2)

* Stat-T

0492-01-#125 1400W/~240V 43"-00-HE Rod-Cal

 

Ballast

 

 

3212-01-#125

 

164-120-WH3

 

Ballast

 

 

3212-01-#125

 

164-120-WH3

 

Ballast

 

 

3212-01-#125

 

164-120-WH3

H2

L2

 

 

L1

 

H1

P

L

Toggle-LIGHTS 0307-01-#125

#225* -01-3301 Snap-OnT-Stat 20N11T002-L250 ON:183°F/OFF:210°F

*T-Stat

Infite Control

H2

Stat-T*

Infite Control

H2 H1

 

 

#125 - 01 - 0492

1400W/~240V

 

 

 

43"-00-HE Rod-Cal

 

 

 

0492-01-#125

1400W/~240V

H1

 

 

43"-00-HE Rod-Cal

 

L2

 

andcalibrationinstructions.

L1

L

wiring

P

 

control

L2

 

forwater

L1

L

and3

P

2

 

 

Seesheets

DrawingNo.:

W6000027

Sheet 1 of3

ProjectTitle:

IndividualWellsHotFoodSelf-ServiceCounters

ASH-S/ESH-S-RGSH-L/S-12',10WellsDrawingTitle:

 

 

 

 

 

 

10

Bulb Stat-T

L

 

5

Bulb Stat-T

L

L

 

 

 

 

 

 

 

 

 

 

9

Bulb Stat-T

L

 

 

 

 

 

 

 

 

 

4

 

L

L

Hz

 

 

 

 

Bulb Stat-T

-50/60

 

 

 

WELLFOODHOTAPW12x20(10)UNIT 1104-01-#175 ~208/240VAC1200/1600W

32

 

LL

LL

CircuitI 208/240VAC-3Ph

78

Bulb Stat-T

LL

 

 

 

 

 

 

 

 

 

 

Bulb Stat-T

 

 

 

 

 

 

 

 

 

 

 

 

 

Bulb Stat-T

 

 

 

Bulb Stat-T

 

 

 

 

 

 

 

 

 

 

 

 

6

Bulb Stat-T

L

 

 

 

 

 

 

 

 

 

1

Bulb Stat-T

L

L

 

 

 

 

L

L

 

L

CircuitII ~208/240V-3Ph-60Hz

L

 

L

BorisKasrel

BK

04.14.2000

final

DrawnBy:

CheckedBy:

Date:

NextAssembly:

By:

 

 

 

Date:

 

 

Revisions:

No. Description:

CircuitI

LOADS,Amps

~208V ~240V

22.6 26.1

18.2 21.0

14.6 16.8

 

 

 

L1

L2

L3

POWER

SwitchToggle

 

 

s

 

 

 

 

 

 

 

 

 

1001-01-#125

 

 

 

 

 

 

 

 

 

1 Contactor

 

 

 

 

 

WaterFill

ToggleSwitch

socketcontroller

B

TermBlock

L1

L2

L3

N

G

 

Pin#2To

2shtsee

ToTimeDelay seesht2

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

on

 

 

 

 

 

 

 

CircuitII

LOADS,Amps

~208V ~240V

L1 24.8 28.6

L2 27.6 31.9

L3 18.2 21.0

Note:casemustbegrounded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

s

 

 

 

 

 

1001-01-#125

 

 

 

 

 

2 Contactor

 

 

 

 

 

TermBlock

L1

L2

L3

N

G

HussmannCorporation 13770RamonaAvenue Chino,CA.91710 (909)-590-4910 Lic.#:644406

®

39

Image 39
Contents ESH/ESHS Hot Food Family Concealed Loss or Damage This Booklet Contains Information onShipping Damage Apparent Loss or DamageSetting and Joining Uncrating the StandExterior Loading Common END Between Unlike Cases and HOT Cases Corner WedgesInstalling Splashguard Perform After Plumbing and Electrical Access PanelsElectrical Circuit Identification Wiring Color CodeElectrical Service Receptacles When Applicable Field Wiring & Serial Plate AmperageWell Heating System Important Operation TipsControls Overhead Heating SystemAUTO-FILL Operation START-UPCleaning Glass & Mirrors CleaningAntistatic Coatings Broken Glass Removal Clamshell AssemblyInstall Glass Installing Glass SweepPiston Replacement For Prompt ServiceInspect the GAP Between the Glass Panels For RGSMS/RGSD…/FS cases go to Item IGHT-ESH/ESHS-0010 Vertical Adjustment Tips & Troubleshooting W6000025 W6000019W6000021 W6000022Lights Loads,amp15.6 11.0 BallastW6000002 PowerServiceCounter Amps 240V 16.2 22.0 22.3 Load 208V 14.0 19.0 19.3WaterSolenoid Valve 6CommonWell5PanHotFoodServiceCounterAmps 240V 20.3 23.9 24.5 Load 208V 17.5 20.7 21.2 BallastAmps 240V 10.3 Load 208V 24.3 21.0 Fuse Amp 240V 11.9 10.8 Loads 208V 10.5 28.4 22.6 24.5 19.6Overhead InstallationLoading 208V 240V 24.5 19.7 Loading 208V 240V 11.4 11.9Ledge 208V 12.3 12.8208V 31.5 Lights-optional135-120-WH2 WaterLevelSwitch WaterReservoir LevelControllerLoading 208V 240V 31.5 Loading 208V 240V 14.1 14.9RGSH-L/S,OSH Loads,amp 208V 240V 40.0 33.8Loading 208V 240V 15.2 16.7 CasemustbegroundedPilotLight Grounded14.2 ASH,ESH,ESHS,RGSHL,RGSHS,OSH-SSLight 17.315.0 Heater ControlAmp V 240V 16.6 17.5 Mustbegrounded Loads 15.2208 L2 L316.3 18.015.6 17.414.2 Elddirg ,V042~/W0001 EH h/o Wells 1400W/~240V HE o/hW6000014 21.6 Grounded Load,Amp 240V 24.9 18.8 208VW6000016 Amp 240V 26.4 24.1 22.7 Loads 208V 22.9 20.9 19.8~208/240V-3Ø-60Hz 164-120-WH3ASH,ESH/S 13.115.1511.0 10.411.8 RGSH-L/S,RGSHSLoads,Amp 208V 240V 14.1 11.0 Loads,Amp 208V 240V 24.5Loads,amp 208V 240V 16.5 11.4 InstallationOverhead WellW6000021.dft IndividualWellsHotFoodSelf-ServiceCounter 512x27HotFoodWellW6000022.dft HotFoodIndividualWellsServiceCaseCIRCUIT1 W600002550/60 IndividualWellsHotFoodSelf-ServiceCountersOfthecase Ringfrom Eachend Toprotect W600002860Hz ~208/240VOverhead Installation Loads,amp 208V 240V 26.1 21.4 15.3FoodHotIndividual27x12Well ~208/240V1200/1600W IndividualHotFoodWell 51200/1600W/~208/240V Loads,Amp 208V L1 17.5 L2 13.1 L3 13.1Amp 240V 24.3 25.9 Loads 208V 21.0 22.6 Amp 240V 19.2 14.1Loads 208V 16.6 12.2 Appendix A. Temperature Guidelines Coopers Stainless Steel Scour or rub with a damp clothLimited Warranty Model Serial Number

IGHT-ESH/ESHS-0010 specifications

The Hussman IGHT-ESH/ESHS-0010 is a state-of-the-art refrigeration unit designed specifically for commercial applications. Renowned for its durability and efficiency, this unit stands out in the competitive landscape of commercial refrigeration. With a focus on energy conservation and environmental responsibility, the IGHT-ESH/ESHS-0010 incorporates advanced technologies that enhance its performance while reducing operational costs.

One of the standout features of the Hussman IGHT-ESH/ESHS-0010 is its innovative refrigeration system. Utilizing a highly efficient compressor, the unit ensures optimal cooling performance while minimizing energy consumption. This efficiency is further enhanced by the incorporation of variable speed fans, which automatically adjust their speed based on the cooling demand. This feature not only improves energy efficiency but also reduces noise levels, making it suitable for a variety of commercial environments.

The design of the IGHT-ESH/ESHS-0010 emphasizes versatility and adaptability. It is equipped with adjustable shelving and modular components, allowing users to customize the interior layout according to their specific needs. This flexibility makes it an excellent choice for retailers, foodservice establishments, and convenience stores that require dynamic display and storage solutions.

Temperature control is crucial in refrigeration, and the Hussman IGHT-ESH/ESHS-0010 excels in this area. Featuring advanced digital controls and monitoring systems, users can easily set and adjust temperatures to meet their requirements. The unit provides consistent temperature management, which is essential for preserving the quality and safety of perishable products.

Another remarkable aspect of the IGHT-ESH/ESHS-0010 is its focus on sustainability. The unit is designed with environmentally friendly refrigerants that comply with today’s stringent regulations, contributing to reduced greenhouse gas emissions. Additionally, the Hussman brand is committed to energy-efficient solutions that not only benefit the environment but also help businesses save on energy costs.

Finally, the construction of the Hussman IGHT-ESH/ESHS-0010 is robust, featuring high-quality materials that ensure longevity and resilience in a busy commercial setting. Its attractive exterior design ensures that it seamlessly fits into any retail or foodservice environment while providing exceptional cooling performance.

In summary, the Hussman IGHT-ESH/ESHS-0010 is a centerpiece in modern commercial refrigeration. With its combination of energy efficiency, user-friendly features, and sustainable design, it represents a smart investment for businesses aiming to enhance their operational efficiency and environmental stewardship.