hussman IGHT-ESH/ESHS-0010 manual Cleaning Glass & Mirrors, Antistatic Coatings

Page 9

Rev. 0010

User Information cont.

1.Scrub thoroughly,cleaning all surfaces,with soap and hot water.

2.Rinse with hot water, but do not flood.

3.Apply the sanitizing solution according to the manufacturer’s directions.

4.Rinse thoroughly.

5.Dry completely before resuming operation.

CLEANING GLASS & MIRRORS

Only use a soft cloth and mild glass cleaner for cleaning any glass or mirrored components. Be sure to rinse and/or dry completely.

NON-GLARE GLASS

The high optical clarity of this glass is possible due to special coatings on the glass surface itself. To preserve this coating and the optical clarity, keep the glass clean. Windex® or Glass Plus® are the only solutions recom- mended to be used to clean the non-glare glass. The damage to the glass from improper, caustic solutions is irreparable.

In addition to cleaning the glass with the recommended product, there are precautions that should be taken when working and cleaning the inside of the case.

When cleaning the inside of the cases, we recommend that the glass be fully opened and covered to prevent solutions from splashing onto the glass and ruining the coating on the inside.

to the surface. Incorrect cleaning agents or cleaning cloths can cause micro scratching of the surface,causing the plastic to haze over time.

CLEANING

Hussmann recommends using a clean damp chamois, , or a paper towel marked as dust and abrasive free with 210® Plastic Cleaner and Polish available by calling Sumner Labs at 1-800-542-8656. Hard, rough cloths or paper towels will scratch the acrylic and should not be used.

ANTISTATIC COATINGS

The 210® has proven to be very effective in not only clean- ing and polishing the Plexiglass surface, but also providing anti-static and anti-fog capabilities. This product also seals pores and provides a protective coating.

DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS (these will mar the finish)

CLEANING PRECAUTIONS

WHEN CLEANING:

Never Use a Cleaning or Sanitizing Solution that has an OIL BASE (these will dissolve the butyl sealants) or AMMONIA BASE

(this will corrode the copper components of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

Do Use Water and a Mild Detergent for the Exterior Only!

Do Not Use Abrasives or Steel Wool Scouring Pads (these will mar the finish)

PLEXIGLASS & ACRYLIC CARE

Improper cleaning not only accelerates the cleaning cycle but also degrades the quality of this surface. Normal daily buffing motions can generated static cling attracting dust

9

Image 9
Contents ESH/ESHS Hot Food Family Shipping Damage This Booklet Contains Information onApparent Loss or Damage Concealed Loss or DamageSetting and Joining Uncrating the StandExterior Loading Common END Between Unlike Cases and HOT Cases Corner WedgesInstalling Splashguard Perform After Plumbing and Electrical Access PanelsElectrical Service Receptacles When Applicable Wiring Color CodeField Wiring & Serial Plate Amperage Electrical Circuit IdentificationControls Important Operation TipsOverhead Heating System Well Heating SystemAUTO-FILL Operation START-UPCleaning Glass & Mirrors CleaningAntistatic Coatings Install Glass Clamshell AssemblyInstalling Glass Sweep Broken Glass RemovalPiston Replacement For Prompt ServiceInspect the GAP Between the Glass Panels For RGSMS/RGSD…/FS cases go to Item IGHT-ESH/ESHS-0010 Vertical Adjustment Tips & Troubleshooting W6000021 W6000019W6000022 W600002515.6 11.0 Loads,ampBallast LightsServiceCounter PowerAmps 240V 16.2 22.0 22.3 Load 208V 14.0 19.0 19.3 W6000002Amps 240V 20.3 23.9 24.5 Load 208V 17.5 20.7 21.2 6CommonWell5PanHotFoodServiceCounterBallast WaterSolenoid ValveAmps 240V 10.3 Load 208V 24.3 21.0 Fuse Amp 240V 11.9 10.8 Loads 208V 10.5 28.4 22.6 24.5 19.6Loading 208V 240V 24.5 19.7 InstallationLoading 208V 240V 11.4 11.9 Overhead208V 31.5 208V 12.3 12.8Lights-optional LedgeLoading 208V 240V 31.5 WaterLevelSwitch WaterReservoir LevelControllerLoading 208V 240V 14.1 14.9 135-120-WH2Loading 208V 240V 15.2 16.7 Loads,amp 208V 240V 40.0 33.8Casemustbegrounded RGSH-L/S,OSH14.2 GroundedASH,ESH,ESHS,RGSHL,RGSHS,OSH-SS PilotLight15.0 17.3Heater Control LightAmp V 240V 16.6 17.5 Mustbegrounded Loads 15.2208 L2 L316.3 18.015.6 17.414.2 Elddirg ,V042~/W0001 EH h/o Wells 1400W/~240V HE o/hW6000014 21.6 Grounded Load,Amp 240V 24.9 18.8 208V~208/240V-3Ø-60Hz Amp 240V 26.4 24.1 22.7 Loads 208V 22.9 20.9 19.8164-120-WH3 W6000016511.0 10.411.8 13.115.1RGSH-L/S,RGSHS ASH,ESH/SLoads,Amp 208V 240V 14.1 11.0 Loads,Amp 208V 240V 24.5Overhead InstallationWell Loads,amp 208V 240V 16.5 11.4W6000021.dft IndividualWellsHotFoodSelf-ServiceCounter 512x27HotFoodWellW6000022.dft HotFoodIndividualWellsServiceCaseCIRCUIT1 W600002550/60 IndividualWellsHotFoodSelf-ServiceCounters60Hz W6000028~208/240V Ofthecase Ringfrom Eachend ToprotectOverhead Installation Loads,amp 208V 240V 26.1 21.4 15.3FoodHotIndividual27x12Well ~208/240V1200/1600W IndividualHotFoodWell 51200/1600W/~208/240V Loads,Amp 208V L1 17.5 L2 13.1 L3 13.1Amp 240V 24.3 25.9 Loads 208V 21.0 22.6 Amp 240V 19.2 14.1Loads 208V 16.6 12.2 Appendix A. Temperature Guidelines Coopers Stainless Steel Scour or rub with a damp clothLimited Warranty Model Serial Number

IGHT-ESH/ESHS-0010 specifications

The Hussman IGHT-ESH/ESHS-0010 is a state-of-the-art refrigeration unit designed specifically for commercial applications. Renowned for its durability and efficiency, this unit stands out in the competitive landscape of commercial refrigeration. With a focus on energy conservation and environmental responsibility, the IGHT-ESH/ESHS-0010 incorporates advanced technologies that enhance its performance while reducing operational costs.

One of the standout features of the Hussman IGHT-ESH/ESHS-0010 is its innovative refrigeration system. Utilizing a highly efficient compressor, the unit ensures optimal cooling performance while minimizing energy consumption. This efficiency is further enhanced by the incorporation of variable speed fans, which automatically adjust their speed based on the cooling demand. This feature not only improves energy efficiency but also reduces noise levels, making it suitable for a variety of commercial environments.

The design of the IGHT-ESH/ESHS-0010 emphasizes versatility and adaptability. It is equipped with adjustable shelving and modular components, allowing users to customize the interior layout according to their specific needs. This flexibility makes it an excellent choice for retailers, foodservice establishments, and convenience stores that require dynamic display and storage solutions.

Temperature control is crucial in refrigeration, and the Hussman IGHT-ESH/ESHS-0010 excels in this area. Featuring advanced digital controls and monitoring systems, users can easily set and adjust temperatures to meet their requirements. The unit provides consistent temperature management, which is essential for preserving the quality and safety of perishable products.

Another remarkable aspect of the IGHT-ESH/ESHS-0010 is its focus on sustainability. The unit is designed with environmentally friendly refrigerants that comply with today’s stringent regulations, contributing to reduced greenhouse gas emissions. Additionally, the Hussman brand is committed to energy-efficient solutions that not only benefit the environment but also help businesses save on energy costs.

Finally, the construction of the Hussman IGHT-ESH/ESHS-0010 is robust, featuring high-quality materials that ensure longevity and resilience in a busy commercial setting. Its attractive exterior design ensures that it seamlessly fits into any retail or foodservice environment while providing exceptional cooling performance.

In summary, the Hussman IGHT-ESH/ESHS-0010 is a centerpiece in modern commercial refrigeration. With its combination of energy efficiency, user-friendly features, and sustainable design, it represents a smart investment for businesses aiming to enhance their operational efficiency and environmental stewardship.