Heat Controller A-13 installation instructions Gross Cooling Capacity Btu kW 50,000

Page 29

GENERAL DATA - TGC MODELS

NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]

Model TGC-Series

048A-3K-080

048A-3K-100

048A-3K-135

048A-1K-080

Cooling Performance1

 

 

 

Continued ->

Gross Cooling Capacity Btu [kW]

50,000 [14.65]

50,000 [14.65]

50,000 [14.65]

50,000 [14.65]

EER/SEER2

11.45/13

11.45/13

11.45/13

11.45/13

Nominal CFM/ARI Rated CFM [L/s]

1600/1600 [755/755]

1600/1600 [755/755]

1600/1600 [755/755]

1600/1600 [755/755]

ARI Net Cooling Capacity Btu [kW]

48,000 [14.06]

48,000 [14.06]

48,000 [14.06]

48,000 [14.06]

Net Sensible Capacity Btu [kW]

35,600 [10.43]

35,600 [10.43]

35,600 [10.43]

35,600 [10.43]

Net Latent Capacity Btu [kW]

12,400 [3.63]

12,400 [3.63]

12,400 [3.63]

12,400 [3.63]

Net System Power kW

4.19

4.19

4.19

4.19

 

 

 

 

 

Heating Performance (Gas)3

 

 

 

 

Heating Input Btu [kW]

80,000 [23.44]

100,000 [29.3]

135,000 [39.56]

80,000 [23.44]

Heating Output Btu [kW]

64,800 [18.99]

81,000 [23.73]

109,400 [32.05]

62,500 [18.31]

Temperature Rise Range °F [°C]

30-60 [16.7/33.3]

40-70 [22.2/38.9]

50-80 [27.8/44.4]

30-60 [16.7/33.3]

AFUE %

80

80

80

80

Steady State Efficiency (%)

81

81

81

81

No. Burners

4

5

6

4

No. Stages

1

1

1

1

Gas Connection Pipe Size in. [mm]

0.5 [12.7]

0.5 [12.7]

0.5 [12.7]

0.5 [12.7]

 

 

 

 

 

Compressor

 

 

 

 

No./Type

1/Copeland Scroll

1/Copeland Scroll

1/Copeland Scroll

1/Copeland Scroll

 

 

 

 

 

Outdoor Sound Rating (dB)4

78

78

78

78

 

 

 

 

 

Outdoor Coil - Fin Type

Louvered

Louvered

Louvered

Louvered

Tube Type

Rifled

Rifled

Rifled

Rifled

Tube Size in. [mm] OD

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

Face Area sq. ft. [sq. m]

16.59 [1.54]

16.56 [1.54]

16.56 [1.54]

16.56 [1.54]

Rows / FPI [FPcm]

2 / 22 [9]

2 / 22 [9]

2 / 22 [9]

2 / 22 [9]

 

 

 

 

 

Indoor Coil - Fin Type

Corrugated

Corrugated

Corrugated

Corrugated

Tube Type

Rifled

Rifled

Rifled

Rifled

Tube Size in. [mm]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

0.375 [9.5]

Face Area sq. ft. [sq. m]

5.17 [0.48]

5.17 [0.48]

5.17 [0.48]

5.17 [0.48]

Rows / FPI [FPcm]

3 / 15 [6]

3 / 15 [6]

3 / 15 [6]

3 / 15 [6]

Refrigerant Control

TX Valves

TX Valves

TX Valves

TX Valves

Drain Connection No./Size in. [mm]

1/0.75 [19.05]

1/0.75 [19.05]

1/0.75 [19.05]

1/0.75 [19.05]

 

 

 

 

 

Outdoor Fan - Type

Propeller

Propeller

Propeller

Propeller

No. Used/Diameter in. [mm]

1/24 [609.6]

1/24 [609.6]

1/24 [609.6]

1/24 [609.6]

Drive Type/No. Speeds

Direct/1

Direct/1

Direct/1

Direct/1

CFM [L/s]

3680 [1737]

3680 [1737]

3680 [1737]

3680 [1737]

No. Motors/HP

1 at 1/3 HP

1 at 1/3 HP

1 at 1/3 HP

1 at 1/3 HP

Motor RPM

1075

1075

1075

1075

 

 

 

 

 

Indoor Fan - Type

FC Centrifugal

FC Centrifugal

FC Centrifugal

FC Centrifugal

No. Used/Diameter in. [mm]

1/10x10 [254x254]

1/10x10 [254x254]

1/10x10 [254x254]

1/10x10 [254x254]

Drive Type/No. Speeds

Direct/3

Direct/3

Direct/3

Direct/3

No. Motors

1

1

1

1

Motor HP

1/2

1/2

1/2

1/2

Motor RPM

1075

1075

1075

1075

Motor Frame Size

48

48

48

48

 

 

 

 

 

Filter - Type

Disposable

Disposable

Disposable

Disposable

Furnished

Yes

Yes

Yes

Yes

(NO.) Size Recommended in. [mm x mm x mm]

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

 

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

(1)1x16x25 [25x406x635]

 

 

 

 

 

Refrigerant Charge Oz. [g]

165 [4678]

165 [4678]

165 [4678]

165 [4678]

 

 

 

 

 

Weights

 

 

 

 

Net Weight lbs. [kg]

580 [263]

580 [263]

585 [265]

580 [263]

Ship Weight lbs. [kg]

587 [266]

587 [266]

592 [269]

587 [266]

 

 

 

 

 

NOTES:

1.Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360.

2.EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.

3.Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.

4.Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.

29

Image 29
Contents Heat Controller Table of Contents III. Checking Product Received IV. SpecificationsII. Introduction Quick Reference Guide For R-410A Safety InformationVI. Unit Dimensions Supply and Return Dimensions Location Considerations VII. InstallationOutside Slab Installation Clearances Cover Panel INSTALLATION/CONVERSION ProcedureAttaching Exhaust and Combustion AIR Inlet Hoods Ductwork Rooftop InstallationIs Very Important and the INSTALLER’S Responsibility Return AIR Rooftop UNI GAS Connection Roof or Ground Level InstallationVIII. GAS SUPPLY, Condensate Drain and Piping NOx Models LP ConversionRegulator cap securely Adjusting or Checking Furnace InputPower Supply IX. WiringCondensate Drain Condensate DrainRecommended Branch Circuit Disconnect Location Branch Circuit Ampacity Supply Wire LENGTH-FEETThermostat Internal WiringHOOK-UP Normal Furnace Operating Sequence Furnace Section Controls Ignition SystemTo Shut Down Furnace Operating InstructionsXI. System Operating Information Furnace Section Maintenance Lubrication Cooling Section MaintenanceTroubleshooting Replacement PartsWiring Diagrams ChargingIntegrated Furnace Control Speed TAP Block Page Nominal Sizes 3-5 Tons 10.6-17.6 kW XII. General Data TGC ModelsGeneral Data TGC Models Gross Cooling Capacity Btu kW 50,000 Gross Cooling Capacity Btu kW 50,000 61,000 Gross Cooling Capacity Btu kW 61,000 Electrical Data TGC Series XIII. MiscellaneousDIRECT-DRIVE Blower 208 Airflow Performance DriveGAS Electric Units TGC DIRECT-DRIVE 230 Airflow Performance GASCFM Air Delivery/RPM/Watts-460 Volts DIRECT-DRIVE 460 Airflow PerformanceGAS Electric Units TGC Range 1090 Motor 1/2 H.P. 1750 RPM 910 TON 13 Seer Models Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 14 Seer Cooling Trouble Shooting Chart Furnace Troubleshooting Guide Page Page

A-13 specifications

The Heat Controller A-13 is an innovative and efficient heating solution designed to provide optimal comfort while reducing energy consumption. This advanced unit stands out in the market due to its combination of cutting-edge technologies and user-centric features, making it an ideal choice for both residential and commercial applications.

One of the main features of the A-13 is its high energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating of up to 23, the unit not only lowers energy bills but also minimizes the carbon footprint, making it an environmentally friendly option. This efficiency is further enhanced by the use of variable speed inverter technology, which allows the unit to modulate its output based on the specific heating demand. This ensures a more consistent and comfortable indoor environment while avoiding the energy wastage associated with traditional fixed-speed systems.

The A-13 incorporates state-of-the-art smart technology, enabling users to control their heating system remotely. Through a dedicated mobile application, homeowners can adjust settings, monitor energy consumption, and receive maintenance alerts directly from their smartphones. This level of control offers convenience and ensures that the space is always comfortable upon arrival.

In addition to smart capabilities, the A-13 is designed with ultra-quiet operation in mind. Thanks to its advanced compressor and fan technology, the unit operates at sound levels as low as 26 decibels, ensuring a peaceful atmosphere even when the heating system is in operation. This is particularly beneficial for environments where noise can be a distraction, such as bedrooms or offices.

The heat exchanger technology used in the A-13 further contributes to its high performance. The unit features a corrosion-resistant, gold-fin coating that enhances durability and heat transfer efficiency. This not only extends the lifespan of the unit but also helps maintain optimal performance over time.

Safety features are also a priority in the A-13 design. The unit includes multiple safety mechanisms, such as overheating protection and automatic shut-off functions, ensuring safe operation even during extended use.

Overall, the Heat Controller A-13 represents a blend of efficiency, performance, and user-friendly technology, making it a top choice for those seeking reliable and sustainable heating solutions in their spaces. With its combination of smart controls, quiet operation, and robust safety features, the A-13 is indeed a leader in modern heating solutions.