Heat Controller A-13 Drive, GAS Electric Units TGC, DIRECT-DRIVE Blower 208 Airflow Performance

Page 33

DIRECT-DRIVE BLOWER 208 AIRFLOW PERFORMANCE

 

Motor Speed

Heating

Manufacturer

Blower Size/

 

 

 

 

CFM Air Delivery/RPM/Watts-208 VOLTS

 

 

Unit Model

From Factory

Input

Recommended

Motor

 

 

 

 

 

 

 

 

 

Motor HP #

 

 

 

External Static Pressure-Inches W.C.

 

 

BTU/hr

Air-Flow Range

Speed

 

 

 

 

 

 

 

 

of Speeds

 

 

 

 

 

 

Cool

Heat

[kW]

(Min / Max) CFM

 

 

 

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

 

 

 

 

 

 

 

 

 

80,000

 

 

Low

CFM

1210

1193

1175

1155

1125

1075

1015

925

 

 

Low

 

10x10

Watts

450

400

395

385

380

375

370

360

 

 

[23.45]

 

 

 

 

 

 

 

CFM

1515

1500

1475

1450

1405

1350

1275

1180

TGC036A

Low

 

 

1050 / 1350

1/2

Med

 

120,000

3 Speed

Watts

525

515

510

505

490

475

460

445

 

 

 

 

 

 

 

Med

 

(PSC)

 

CFM

1680

1650

1625

1580

1530

1460

1390

1280

 

 

[35.17]

 

 

High

 

 

 

 

 

Watts

650

640

630

610

580

560

545

515

 

 

 

 

 

 

 

 

 

 

80,000

 

 

Low

CFM

1210

1193

1175

1155

1125

1075

1015

925

 

 

Low

 

10x10

Watts

450

400

395

385

380

375

370

360

 

 

[23.45]

 

 

 

 

 

 

 

CFM

1515

1500

1475

1450

1405

1350

1275

1180

TGC036A

Med

 

 

1225 / 1575

1/2

Med

 

120,000

3 Speed

Watts

525

515

510

505

490

475

460

445

 

 

 

 

 

 

 

Med

 

(PSC)

 

CFM

1680

1650

1625

1580

1530

1460

1390

1280

 

 

[35.17]

 

 

High

 

 

 

 

 

Watts

650

640

630

610

580

560

545

515

 

 

 

 

 

 

 

 

 

Low

80,000

 

 

Low

CFM

1210

1193

1175

1155

1125

1075

1015

925

 

 

[23.45]

 

10x10

Watts

450

400

395

385

380

375

370

360

 

 

 

 

 

TGC036A

Med

Med

100,000

1400 / 1800

1/2

Med

CFM

1515

1500

1475

1450

1405

1350

1275

1180

[29.31]

3 Speed

Watts

525

515

510

505

490

475

460

445

 

 

 

 

 

 

 

High

135,000

 

(PSC)

High

CFM

1680

1650

1625

1580

1530

1460

1390

1280

 

 

 

 

 

 

[39.56]

 

 

Watts

650

640

630

610

580

560

545

515

 

 

 

 

 

 

 

 

 

100,000

 

 

Low

CFM

1575

1536

1496

1457

1417

1377

1338

1298

 

 

Low

 

10x10

Watts

297

314

330

347

364

381

397

414

 

 

[29.31]

 

 

 

 

 

 

 

CFM

1985

1954

1919

1876

1824

1759

1679

1581

TGC036A

Med

 

 

1750 / 2250

1

Med

 

135,000

3 Speed

Watts

535

553

574

593

606

609

599

572

 

 

 

 

 

 

 

High

 

(X-13)

 

CFM

2431

2372

2306

2228

2138

2032

1907

1762

 

 

[39.56]

 

 

High

 

 

 

 

 

Watts

970

981

964

926

872

806

736

665

 

 

 

 

 

 

 

DIRECT

INDOOR AIRFLOW PERFORMANCE FOR 3-5

DRIVE

TON PACKAGE

 

GAS ELECTRIC UNITS – TGC

33

Image 33
Contents Heat Controller Table of Contents IV. Specifications II. IntroductionIII. Checking Product Received Quick Reference Guide For R-410A Safety InformationVI. Unit Dimensions Supply and Return Dimensions Location Considerations VII. InstallationOutside Slab Installation Cover Panel INSTALLATION/CONVERSION Procedure Attaching Exhaust and Combustion AIR Inlet HoodsClearances Rooftop Installation Is Very Important and the INSTALLER’S ResponsibilityDuctwork Return AIR Rooftop UNI Roof or Ground Level Installation VIII. GAS SUPPLY, Condensate Drain and PipingGAS Connection NOx Models LP ConversionRegulator cap securely Adjusting or Checking Furnace InputPower Supply IX. WiringCondensate Drain Condensate DrainRecommended Branch Circuit Disconnect Location Branch Circuit Ampacity Supply Wire LENGTH-FEETInternal Wiring HOOK-UPThermostat Normal Furnace Operating Sequence Furnace Section Controls Ignition SystemTo Shut Down Furnace Operating InstructionsXI. System Operating Information Furnace Section Maintenance Lubrication Cooling Section MaintenanceTroubleshooting Replacement PartsWiring Diagrams ChargingIntegrated Furnace Control Speed TAP Block Page Nominal Sizes 3-5 Tons 10.6-17.6 kW XII. General Data TGC ModelsGeneral Data TGC Models Gross Cooling Capacity Btu kW 50,000 Gross Cooling Capacity Btu kW 50,000 61,000 Gross Cooling Capacity Btu kW 61,000 Electrical Data TGC Series XIII. MiscellaneousDrive GAS Electric Units TGCDIRECT-DRIVE Blower 208 Airflow Performance DIRECT-DRIVE 230 Airflow Performance GASCFM Air Delivery/RPM/Watts-460 Volts DIRECT-DRIVE 460 Airflow PerformanceGAS Electric Units TGC Range 1090 Motor 1/2 H.P. 1750 RPM 910 TON 13 Seer Models Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 14 Seer Cooling Trouble Shooting Chart Furnace Troubleshooting Guide Page Page

A-13 specifications

The Heat Controller A-13 is an innovative and efficient heating solution designed to provide optimal comfort while reducing energy consumption. This advanced unit stands out in the market due to its combination of cutting-edge technologies and user-centric features, making it an ideal choice for both residential and commercial applications.

One of the main features of the A-13 is its high energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating of up to 23, the unit not only lowers energy bills but also minimizes the carbon footprint, making it an environmentally friendly option. This efficiency is further enhanced by the use of variable speed inverter technology, which allows the unit to modulate its output based on the specific heating demand. This ensures a more consistent and comfortable indoor environment while avoiding the energy wastage associated with traditional fixed-speed systems.

The A-13 incorporates state-of-the-art smart technology, enabling users to control their heating system remotely. Through a dedicated mobile application, homeowners can adjust settings, monitor energy consumption, and receive maintenance alerts directly from their smartphones. This level of control offers convenience and ensures that the space is always comfortable upon arrival.

In addition to smart capabilities, the A-13 is designed with ultra-quiet operation in mind. Thanks to its advanced compressor and fan technology, the unit operates at sound levels as low as 26 decibels, ensuring a peaceful atmosphere even when the heating system is in operation. This is particularly beneficial for environments where noise can be a distraction, such as bedrooms or offices.

The heat exchanger technology used in the A-13 further contributes to its high performance. The unit features a corrosion-resistant, gold-fin coating that enhances durability and heat transfer efficiency. This not only extends the lifespan of the unit but also helps maintain optimal performance over time.

Safety features are also a priority in the A-13 design. The unit includes multiple safety mechanisms, such as overheating protection and automatic shut-off functions, ensuring safe operation even during extended use.

Overall, the Heat Controller A-13 represents a blend of efficiency, performance, and user-friendly technology, making it a top choice for those seeking reliable and sustainable heating solutions in their spaces. With its combination of smart controls, quiet operation, and robust safety features, the A-13 is indeed a leader in modern heating solutions.