Heat Controller A-13 installation instructions Gas, DIRECT-DRIVE 230 Airflow Performance

Page 34

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR AIRFLOW

DIRECT-DRIVE 230 AIRFLOW PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor Speed

Heating

Manufacturer

Blower Size/

 

 

 

 

CFM Air Delivery/RPM/Watts-230 VOLTS

 

 

 

Unit Model

From Factory

Input

Recommended

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor HP #

 

 

 

External Static Pressure-Inches W.C.

 

 

 

 

BTU/hr

Air-Flow Range

Speed

 

 

 

 

 

 

 

 

 

 

of Speeds

 

 

 

 

 

 

 

 

Cool

Heat

[kW]

(Min / Max) CFM

 

 

 

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

 

 

 

 

 

 

 

 

 

 

 

 

Low

80,000

 

 

Low

CFM

1400

1375

1360

1335

1305

1255

1210

1100

 

 

 

 

[23.45]

 

10x10

Watts

470

460

455

450

440

435

425

410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1685

1620

1580

1550

1500

1430

1350

1230

 

 

TGC036A

Low

Med

120,000

1050 / 1350

1/2

Med

 

 

[35.17]

3 Speed

Watts

635

600

580

570

550

535

505

475

 

FOR3-5

 

 

 

 

 

 

 

 

 

 

 

(PSC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

CFM

1870

1830

1790

1730

1660

1580

1500

1375

DIRECT

 

 

 

 

 

 

 

 

 

120,000

 

1/2

CFM

1685

1620

1580

1550

1500

1430

1350

1230

 

 

 

 

 

 

 

Watts

780

760

740

700

660

635

600

555

 

 

 

 

Low

80,000

 

 

Low

CFM

1400

1375

1360

1335

1305

1255

1210

1100

 

 

 

 

[23.45]

 

10x10

Watts

470

460

455

450

440

435

425

410

 

 

 

 

 

 

 

 

 

TGC042A

Med

Med

 

1225 / 1575

Med

 

 

 

 

 

 

 

 

 

DRIVE

TONPACKAGE

[35.17]

3 Speed

 

 

 

 

 

 

 

 

 

Watts

635

600

580

570

550

535

505

475

 

 

 

 

 

 

 

 

135,000

 

(PSC)

 

CFM

1870

1830

1790

1730

1660

1580

1500

1375

 

 

 

 

 

(PSC)

High

CFM

1870

1830

1790

1730

1660

1580

1500

1375

 

 

 

 

 

 

 

 

 

Watts

780

760

740

700

660

635

600

555

 

 

 

 

Low

80,000

 

 

Low

CFM

1400

1375

1360

1335

1305

1255

1210

1100

 

 

 

 

[23.45]

 

10x10

Watts

470

460

455

450

440

435

425

410

 

 

 

 

 

 

 

 

 

TGC048A

Med

Med

100,000

1400 / 1800

1/2

Med

CFM

1685

1620

1580

1550

1500

1430

1350

1230

 

 

[29.31]

3 Speed

Watts

635

600

580

570

550

535

505

475

 

 

 

 

 

 

 

 

 

 

 

High

[39.56]

 

 

High

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts

780

760

740

700

660

635

600

555

 

GAS

 

 

 

 

 

 

 

 

 

Low

100,000

 

 

Low

CFM

1575

1536

1496

1457

1417

1377

1338

1298

 

 

 

[29.31]

 

10x10

Watts

297

314

330

347

364

381

397

414

 

 

 

 

 

 

 

CFM

1985

1954

1919

1876

1824

1759

1679

1581

 

ELECTRICUNITS–TGC

TGC060A

Med

 

 

1750 / 2250

1

Med

 

 

 

 

 

 

 

3 Speed

Watts

535

553

574

593

606

609

599

572

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(X-13)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

135,000

 

High

CFM

2431

2372

2306

2228

2138

2032

1907

1762

 

 

 

 

 

 

 

 

 

 

[39.56]

 

 

Watts

970

981

964

926

872

806

736

665

 

 

 

 

 

 

 

 

 

 

Image 34
Contents Heat Controller Table of Contents II. Introduction IV. SpecificationsIII. Checking Product Received Safety Information Quick Reference Guide For R-410AVI. Unit Dimensions Supply and Return Dimensions VII. Installation Location ConsiderationsOutside Slab Installation Attaching Exhaust and Combustion AIR Inlet Hoods Cover Panel INSTALLATION/CONVERSION ProcedureClearances Is Very Important and the INSTALLER’S Responsibility Rooftop InstallationDuctwork Return AIR Rooftop UNI VIII. GAS SUPPLY, Condensate Drain and Piping Roof or Ground Level InstallationGAS Connection LP Conversion NOx ModelsAdjusting or Checking Furnace Input Regulator cap securelyCondensate Drain IX. WiringPower Supply Condensate DrainBranch Circuit Ampacity Supply Wire LENGTH-FEET Recommended Branch Circuit Disconnect LocationHOOK-UP Internal WiringThermostat Furnace Section Controls Ignition System Normal Furnace Operating SequenceOperating Instructions To Shut Down FurnaceXI. System Operating Information Furnace Section Maintenance Cooling Section Maintenance LubricationWiring Diagrams Replacement PartsTroubleshooting ChargingIntegrated Furnace Control Speed TAP Block Page XII. General Data TGC Models Nominal Sizes 3-5 Tons 10.6-17.6 kWGeneral Data TGC Models Gross Cooling Capacity Btu kW 50,000 Gross Cooling Capacity Btu kW 50,000 61,000 Gross Cooling Capacity Btu kW 61,000 XIII. Miscellaneous Electrical Data TGC SeriesGAS Electric Units TGC DriveDIRECT-DRIVE Blower 208 Airflow Performance GAS DIRECT-DRIVE 230 Airflow PerformanceDIRECT-DRIVE 460 Airflow Performance CFM Air Delivery/RPM/Watts-460 VoltsGAS Electric Units TGC Range 1090 Motor 1/2 H.P. 1750 RPM 910 TON 13 Seer Models Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 14 Seer Cooling Trouble Shooting Chart Furnace Troubleshooting Guide Page Page

A-13 specifications

The Heat Controller A-13 is an innovative and efficient heating solution designed to provide optimal comfort while reducing energy consumption. This advanced unit stands out in the market due to its combination of cutting-edge technologies and user-centric features, making it an ideal choice for both residential and commercial applications.

One of the main features of the A-13 is its high energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating of up to 23, the unit not only lowers energy bills but also minimizes the carbon footprint, making it an environmentally friendly option. This efficiency is further enhanced by the use of variable speed inverter technology, which allows the unit to modulate its output based on the specific heating demand. This ensures a more consistent and comfortable indoor environment while avoiding the energy wastage associated with traditional fixed-speed systems.

The A-13 incorporates state-of-the-art smart technology, enabling users to control their heating system remotely. Through a dedicated mobile application, homeowners can adjust settings, monitor energy consumption, and receive maintenance alerts directly from their smartphones. This level of control offers convenience and ensures that the space is always comfortable upon arrival.

In addition to smart capabilities, the A-13 is designed with ultra-quiet operation in mind. Thanks to its advanced compressor and fan technology, the unit operates at sound levels as low as 26 decibels, ensuring a peaceful atmosphere even when the heating system is in operation. This is particularly beneficial for environments where noise can be a distraction, such as bedrooms or offices.

The heat exchanger technology used in the A-13 further contributes to its high performance. The unit features a corrosion-resistant, gold-fin coating that enhances durability and heat transfer efficiency. This not only extends the lifespan of the unit but also helps maintain optimal performance over time.

Safety features are also a priority in the A-13 design. The unit includes multiple safety mechanisms, such as overheating protection and automatic shut-off functions, ensuring safe operation even during extended use.

Overall, the Heat Controller A-13 represents a blend of efficiency, performance, and user-friendly technology, making it a top choice for those seeking reliable and sustainable heating solutions in their spaces. With its combination of smart controls, quiet operation, and robust safety features, the A-13 is indeed a leader in modern heating solutions.