Heat Controller A-13 installation instructions TON Cooling 13 Seer

Page 47

FIGURE 30

SYSTEM CHARGE CHARTS

3 TON COOLING - 13 SEER

525

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

475

 

 

 

 

 

 

 

 

 

115

 

 

 

 

 

 

 

 

 

 

450

 

 

 

 

 

 

 

 

 

 

425

 

 

 

 

 

 

 

 

 

105

400

 

 

 

 

 

 

 

 

 

 

375

 

 

 

 

 

 

 

 

 

95

350

 

 

 

 

 

 

 

 

 

 

325

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

275

 

 

 

 

 

 

 

 

 

 

250

 

 

 

 

 

 

 

 

 

65

225

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

200

 

 

 

 

 

 

 

 

 

 

175

 

 

 

 

 

 

 

 

 

 

120

125

130

135

140

145

150

155

160

165

170

 

 

 

 

 

 

 

 

 

 

92-102259-01-01

47

Image 47
Contents Heat Controller Table of Contents III. Checking Product Received IV. SpecificationsII. Introduction Quick Reference Guide For R-410A Safety InformationVI. Unit Dimensions Supply and Return Dimensions Location Considerations VII. InstallationOutside Slab Installation Clearances Cover Panel INSTALLATION/CONVERSION ProcedureAttaching Exhaust and Combustion AIR Inlet Hoods Ductwork Rooftop InstallationIs Very Important and the INSTALLER’S Responsibility Return AIR Rooftop UNI GAS Connection Roof or Ground Level InstallationVIII. GAS SUPPLY, Condensate Drain and Piping NOx Models LP ConversionRegulator cap securely Adjusting or Checking Furnace InputCondensate Drain IX. WiringPower Supply Condensate DrainRecommended Branch Circuit Disconnect Location Branch Circuit Ampacity Supply Wire LENGTH-FEETThermostat Internal WiringHOOK-UP Normal Furnace Operating Sequence Furnace Section Controls Ignition SystemTo Shut Down Furnace Operating InstructionsXI. System Operating Information Furnace Section Maintenance Lubrication Cooling Section MaintenanceCharging Replacement PartsTroubleshooting Wiring DiagramsIntegrated Furnace Control Speed TAP Block Page Nominal Sizes 3-5 Tons 10.6-17.6 kW XII. General Data TGC ModelsGeneral Data TGC Models Gross Cooling Capacity Btu kW 50,000 Gross Cooling Capacity Btu kW 50,000 61,000 Gross Cooling Capacity Btu kW 61,000 Electrical Data TGC Series XIII. MiscellaneousDIRECT-DRIVE Blower 208 Airflow Performance DriveGAS Electric Units TGC DIRECT-DRIVE 230 Airflow Performance GASCFM Air Delivery/RPM/Watts-460 Volts DIRECT-DRIVE 460 Airflow PerformanceGAS Electric Units TGC Range 1090 Motor 1/2 H.P. 1750 RPM 910 TON 13 Seer Models Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 14 Seer Cooling Trouble Shooting Chart Furnace Troubleshooting Guide Page Page

A-13 specifications

The Heat Controller A-13 is an innovative and efficient heating solution designed to provide optimal comfort while reducing energy consumption. This advanced unit stands out in the market due to its combination of cutting-edge technologies and user-centric features, making it an ideal choice for both residential and commercial applications.

One of the main features of the A-13 is its high energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating of up to 23, the unit not only lowers energy bills but also minimizes the carbon footprint, making it an environmentally friendly option. This efficiency is further enhanced by the use of variable speed inverter technology, which allows the unit to modulate its output based on the specific heating demand. This ensures a more consistent and comfortable indoor environment while avoiding the energy wastage associated with traditional fixed-speed systems.

The A-13 incorporates state-of-the-art smart technology, enabling users to control their heating system remotely. Through a dedicated mobile application, homeowners can adjust settings, monitor energy consumption, and receive maintenance alerts directly from their smartphones. This level of control offers convenience and ensures that the space is always comfortable upon arrival.

In addition to smart capabilities, the A-13 is designed with ultra-quiet operation in mind. Thanks to its advanced compressor and fan technology, the unit operates at sound levels as low as 26 decibels, ensuring a peaceful atmosphere even when the heating system is in operation. This is particularly beneficial for environments where noise can be a distraction, such as bedrooms or offices.

The heat exchanger technology used in the A-13 further contributes to its high performance. The unit features a corrosion-resistant, gold-fin coating that enhances durability and heat transfer efficiency. This not only extends the lifespan of the unit but also helps maintain optimal performance over time.

Safety features are also a priority in the A-13 design. The unit includes multiple safety mechanisms, such as overheating protection and automatic shut-off functions, ensuring safe operation even during extended use.

Overall, the Heat Controller A-13 represents a blend of efficiency, performance, and user-friendly technology, making it a top choice for those seeking reliable and sustainable heating solutions in their spaces. With its combination of smart controls, quiet operation, and robust safety features, the A-13 is indeed a leader in modern heating solutions.