Heat Controller A-13 installation instructions VII. Installation, Location Considerations

Page 7

!WARNING

NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME. USE A COMMERCIALLY AVAILABLE SOAP SOLUTION MADE SPECIFICALLY FOR THE DETECTION OF LEAKS TO CHECK ALL CONNECTIONS, AS SPECIFIED IN GAS SUPPLY AND PIPING SECTION OF THESE INSTRUCTIONS.

!WARNING

ALWAYS INSTALL UNIT TO OPER- ATE WITHIN THE UNIT'S INTEND- ED TEMPERATURE-RISE RANGE WITH A DUCT SYSTEM WHICH HAS AN EXTERNAL STATIC PRES- SURE WITHIN THE ALLOWABLE RANGE, AS SPECIFIED IN DUCT- ING SECTION OF THESE INSTRUC- TIONS. SEE ALSO UNIT RATING PLATE.

!WARNING

WHEN A UNIT IS INSTALLED SO THAT SUPPLY DUCTS CARRY AIR CIRCULATED BY THE UNIT TO AREAS OUTSIDE THE SPACE CON- TAINING THE UNIT, THE RETURN AIR SHALL ALSO BE HANDLED BY DUCT(S) SEALED TO THE UNIT CASING AND TERMINATING OUT- SIDE THE SPACE CONTAINING THE UNIT.

VII. INSTALLATION

A. GENERAL

Install this unit in accordance with The American National Standard Z223.1-latest edition booklet entitled “National Fuel Gas Code,” and the requirements or codes of the local utility or other authority having jurisdiction.

Additional helpful publications available from the “National Fire Protection Association” are: NFPA-90A - Installation of Air Conditioning and Ventilating Systems 1985 or latest edition. NFPA-90B - Warm Air Heating and Air Conditioning Systems 1984.

These publications are available from:

National Fire Protection Association, Inc. 1 Batterymarch Park

Quincy, MA 02169-7471 www.nfpa.org

1.PRE-INSTALLATION CHECK-POINTS — Before attempting any installation, care- fully consider the following points:

Structural strength of supporting members (Rooftop Installation)

Clearances and provision for servicing Power supply and wiring

Gas supply and piping

Air duct connections and sizing Drain facilities and connections Location for minimum noise and vibration - away from bedroom

windows

2.LOCATION CONSIDERATIONS

The metal parts of this unit may be subject to rust or deterioration in adverse envi- ronmental conditions. This oxidation could shorten the equipment’s useful life. Salt spray, fog or mist in seacoast areas, sulphur or chlorine from lawn watering systems, and various chemical contaminants from industries such as paper mills and petrole- um refineries are especially corrosive.

If the unit is to be installed in an area where contaminants are likely to be a problem, give special attention to the equipment location and exposure.

1.Avoid having lawn sprinkler heads spray directly on the unit cabinet.

2.In coastal areas locate the unit on the side of the building away from the water- front.

3.Shielding by a fence or shrubs may give some protection.

!WARNING

DISCONNECT ALL POWER TO UNIT BEFORE STARTING MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN PER- SONAL INJURY OR DEATH. REGULAR MAINTENANCE WILL REDUCE THE BUILDUP OF CONTAMINANTS AND HELP TO PROTECT THE UNIT’S FINISH.

1.Frequent washing of the cabinet, fan blade and coil with fresh water will remove most of the salt or other contaminants that build up on the unit.

2.Regular cleaning and waxing of the cabinet with a good automobile polish will pro- vide some protection.

3.A good liquid cleaner may be used several times a year to remove matter that will not wash off with water.

Several different types of protective coatings are offered in some areas. These coatings may provide some benefit, but the effectiveness of such coating materials cannot be ver- ified by the equipment manufacturer.

The best protection is frequent cleaning, maintenance and minimal exposure to contaminants.

7

Image 7
Contents Heat Controller Table of Contents II. Introduction IV. SpecificationsIII. Checking Product Received Quick Reference Guide For R-410A Safety InformationVI. Unit Dimensions Supply and Return Dimensions Location Considerations VII. InstallationOutside Slab Installation Attaching Exhaust and Combustion AIR Inlet Hoods Cover Panel INSTALLATION/CONVERSION ProcedureClearances Is Very Important and the INSTALLER’S Responsibility Rooftop InstallationDuctwork Return AIR Rooftop UNI VIII. GAS SUPPLY, Condensate Drain and Piping Roof or Ground Level InstallationGAS Connection NOx Models LP ConversionRegulator cap securely Adjusting or Checking Furnace InputCondensate Drain IX. WiringPower Supply Condensate DrainRecommended Branch Circuit Disconnect Location Branch Circuit Ampacity Supply Wire LENGTH-FEETHOOK-UP Internal WiringThermostat Normal Furnace Operating Sequence Furnace Section Controls Ignition SystemTo Shut Down Furnace Operating InstructionsXI. System Operating Information Furnace Section Maintenance Lubrication Cooling Section MaintenanceCharging Replacement PartsTroubleshooting Wiring DiagramsIntegrated Furnace Control Speed TAP Block Page Nominal Sizes 3-5 Tons 10.6-17.6 kW XII. General Data TGC ModelsGeneral Data TGC Models Gross Cooling Capacity Btu kW 50,000 Gross Cooling Capacity Btu kW 50,000 61,000 Gross Cooling Capacity Btu kW 61,000 Electrical Data TGC Series XIII. MiscellaneousGAS Electric Units TGC DriveDIRECT-DRIVE Blower 208 Airflow Performance DIRECT-DRIVE 230 Airflow Performance GASCFM Air Delivery/RPM/Watts-460 Volts DIRECT-DRIVE 460 Airflow PerformanceGAS Electric Units TGC Range 1090 Motor 1/2 H.P. 1750 RPM 910 TON 13 Seer Models Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 13 Seer TON Cooling 14 Seer Cooling Trouble Shooting Chart Furnace Troubleshooting Guide Page Page

A-13 specifications

The Heat Controller A-13 is an innovative and efficient heating solution designed to provide optimal comfort while reducing energy consumption. This advanced unit stands out in the market due to its combination of cutting-edge technologies and user-centric features, making it an ideal choice for both residential and commercial applications.

One of the main features of the A-13 is its high energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating of up to 23, the unit not only lowers energy bills but also minimizes the carbon footprint, making it an environmentally friendly option. This efficiency is further enhanced by the use of variable speed inverter technology, which allows the unit to modulate its output based on the specific heating demand. This ensures a more consistent and comfortable indoor environment while avoiding the energy wastage associated with traditional fixed-speed systems.

The A-13 incorporates state-of-the-art smart technology, enabling users to control their heating system remotely. Through a dedicated mobile application, homeowners can adjust settings, monitor energy consumption, and receive maintenance alerts directly from their smartphones. This level of control offers convenience and ensures that the space is always comfortable upon arrival.

In addition to smart capabilities, the A-13 is designed with ultra-quiet operation in mind. Thanks to its advanced compressor and fan technology, the unit operates at sound levels as low as 26 decibels, ensuring a peaceful atmosphere even when the heating system is in operation. This is particularly beneficial for environments where noise can be a distraction, such as bedrooms or offices.

The heat exchanger technology used in the A-13 further contributes to its high performance. The unit features a corrosion-resistant, gold-fin coating that enhances durability and heat transfer efficiency. This not only extends the lifespan of the unit but also helps maintain optimal performance over time.

Safety features are also a priority in the A-13 design. The unit includes multiple safety mechanisms, such as overheating protection and automatic shut-off functions, ensuring safe operation even during extended use.

Overall, the Heat Controller A-13 represents a blend of efficiency, performance, and user-friendly technology, making it a top choice for those seeking reliable and sustainable heating solutions in their spaces. With its combination of smart controls, quiet operation, and robust safety features, the A-13 is indeed a leader in modern heating solutions.