EM-70 PLASTER/MORTAR MIXER — ENGINE COMPONENTS

Figure 6. Engine Controls and Components

Initial Servicing

The engine (Figure 6) must be checked for proper lubrication and filled with fuel prior to operation. Refer to the manufacturers engine manual for instructions & details of operation and servicing.

1. Fuel Filler Cap – Remove this cap to add unleaded gasoline to the fuel tank. Make sure cap is tightened securely. DO NOT over fill.

 

DANGER

Explosive

 

Fuel Hazard

Adding fuel to the tank should be done only when the engine is stopped and has had an opportunity to cool down. In the event of a fuel spill,

DO NOT attempt to start the engine until the fuel residue has been completely wiped up, and the area surrounding the engine is dry.

5. Fuel Valve Lever – OPEN to let fuel flow, CLOSE to stop the flow of fuel.

6. Choke Lever – Used in the starting of a cold engine, or in cold weather conditions.The choke enriches the fuel mixture.

7. Air Cleaner – Prevents dirt and other debris from entering the fuel system. Remove wing-nut on top of air filter cannister to gain access to filter element.

Operating the engine without an air

filter, with a damaged air filter, or a

NOTE filter in need of replacement will allow dirt to enter the engine, causing rapid engine wear.

 

WARNING

Burn Hazard

 

 

 

Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operating. NEVER operate the engine with the muffler removed.

8. Spark Plug – Provides spark to the ignition system. Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean spark plug once a week.

9. Muffler – Used to reduce noise and emissions.

10. Fuel Tank – Holds unleaded gasoline. For additional information refer to engine owner's manual.

2. Throttle Lever – Used to adjust engine RPM speed (lever advanced forward SLOW, lever back toward operator FAST).

3. Engine ON/OFF Switch – ON position permits engine starting, OFF position stops engine operations.

4. Recoil Starter (pull rope) – Manual-starting method. Pull the starter grip until resistance is felt, then pull briskly and smoothly.

EM-70 PLASTER/MORTAR MIXER — OPERATION MANUAL — REV. #1 (008/10/04) — PAGE 17

Image 17
Contents Model EM-70S Steel Model EM-70P Plastic Page Email mq@multiquip.com Wilmington Ave Carson, CAEM-70 PLASTER/MORTAR Mixer -TABLE of Contents Direct TOLL-FREE access Capacity Cu. ft 198 liters EM-70 PLASTER/MORTAR Mixer SpecificationsDescription Dimensions in. cm EM-70 PLASTER/MORTAR Mixer DimensionsInstructions for data relative to its safe operation EM-70 PLASTER/MORTAR Mixer Safety Message Alert SymbolsBurn Hazards Respiratory HazardsEquipment Damage Always wear approved eye and hearing protectionNever operate the mixer in an explosive atmosphere or near EM-70 PLASTER/MORTAR Mixer Rules for Safe OperationRead this manual Stand Clear Mixer when in useNever pour or spray water over the engine or electric motor EM-70 PLASTER/MORTAR Mixer -TOWING Guidelines Towing Safety Precautions Regularly InspectTow Bar toVehicle Connection Coupler Only ReplacingWhen Towing EM-70 PLASTER/MORTAR Mixer Safety Chain ConnectionAlways Tow with Tow Bar to Mixer ConnectionMachine Safety Decals EM-70 PLASTER/MORTAR Mixer Operation and Safety DecalsEM-70 PLASTER/MORTAR Mixer General Information Mixer Components EM-70 PLASTER/MORTAR Mixer Major ComponentsInitial Servicing EM-70 PLASTER/MORTAR Mixer Engine ComponentsExplosive Burn HazardElectric Motor Connection EM-70 PLASTER/MORTAR Mixer Electric MotorElectric Motor Important!, when changing the input Electric Motor Voltage SwitchEM-70 PLASTER/MORTAR Mixer Electric Motor Replace the voltage lock-out boltPaddle Blade Adjustment Steel Drum Adjust paddles as shown in aPaddle Blade Adjustment Poly Drum Adjust paddles as shown in bBefore Starting EM-70 PLASTER/MORTAR Mixer InspectionInspection Engine Oil CheckEM-70 PLASTER/MORTAR Mixer Inspection General Safety EM-70 PLASTER/MORTAR Mixer START-UP ProcedureStart-up ProcedureGasonline Engine Respiratory HazardEngine ON/OFF Switch Mixing Dumping EM-70 PLASTER/MORTAR Mixer START-UP/OPERATION ProceduresDump Handle Safety OFF position EM-70 PLASTER/MORTAR Mixer SHUT-DOWN ProceduresStop the engine Engine after every useEngine Maintenance Schedule EM-70 PLASTER/MORTAR Mixer Maintenance EngineExplosive Hazard EM-70 PLASTER/MORTAR Mixer Maintenance EngineMaintenance Ball Socket and Clamp Face Maintenance EM-70 PLASTER/MORTAR Mixer Maintenance MixerDrum Head Seals Drum Bearing Bracket LubricationMain Gear and Drive Pinion Alignment EM-70 PLASTER/MORTAR Mixer Maintenance MixerCountershaft Bearing Lubrication Inspect Tooth Contact between Main Gear and Drive Pinion Grease Fittings Zerk Maintenance Electric MotorGear Lubrication TiresWear/InflationStart all wheel lug nuts by hand Lug NutTorque RequirementsMixer Storage SuspensionKeep Hands Engine Troubleshooting EM-70 PLASTER/MORTAR Mixer -TROUBLESHOOTING EngineWhite EM-70 PLASTER/MORTAR Mixer -TROUBLESHOOTING EngineEM-70PLASTER/MORTARMIXER-TROUBLESHOOTINGMIXER/ELECTRICMOTOR EM-70 PLASTER/MORTAR Mixer -WIRING Diagram Electric Motor Page Multiquip INC

EM-70S, EM-70P specifications

The Multiquip EM-70P and EM-70S are two robust and versatile electric generators designed to provide reliable power for various applications, ranging from construction sites to special events. Both models are renowned for their performance, durability, and efficiency, catering to the needs of contractors, event organizers, and outdoor enthusiasts alike.

One of the standout features of the EM-70P and EM-70S is their powerful engine. The EM-70P is equipped with a 7,000-watt gasoline engine, while the EM-70S comes with a 7,000-watt propane engine. This dual-fuel capability of the EM-70S not only enhances flexibility but also promotes cleaner and more efficient energy consumption. Both generators feature a heavy-duty steel frame that ensures maximum durability and protection against the rigors of job sites.

Technologically, these generators are designed with advanced noise reduction features. The low-noise operation makes them suitable for use in noise-sensitive environments, such as residential areas and events, allowing users to work or host gatherings without disturbing neighbors. Additionally, the EM-70P and EM-70S are equipped with an easy-to-read control panel, featuring circuit breakers and outlets that include multiple 120V and 240V options, ensuring compatibility with a wide range of tools and equipment.

Another notable characteristic of the EM-70P and EM-70S is their portability. Both models come with sturdy wheels and a foldable handle, making them easy to transport on job sites or during events. Their compact size does not compromise power output, as they can easily handle the demands of multiple tools and devices simultaneously.

Safety is also prioritized in the design of these generators. They feature a low-oil shutdown system which automatically turns off the engine when oil levels are critically low, preventing potential damage. Furthermore, the generators are designed to withstand harsh weather conditions, providing peace of mind to users who require dependable power in any environment.

In summary, the Multiquip EM-70P and EM-70S generators combine powerful performance, noise-reduction technology, user-friendly controls, and safety features. Whether you need a reliable power source for construction, outdoor events, or emergency backup, these generators present an ideal solution that meets diverse power needs efficiently and effectively.