Page 13

10Prepare Power Supply

Electrical Specifications

WARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

IMPORTANT

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.

See below for recommended receptacle location

CLR2160 & CLRCO2175

Preferred

 

Location

Acceptable

for CLR2160

Receptacle

Location

24"

7"

1"

CO29

24"

7"

1-1/2"

CO1175

7"

4"

CO29

7"

1-1/2"

CO2175FF

7"

1-1/2"

24"

24"

Minimum

24"

U-Line Electrical / Plumbing Specfications

11

Image 13
Contents Install Guide Table of Contents General Precautions Safety Alert DefinitionsSafety Precautions Product Registration Product Description Exterior CleaningTools / Material Required Inspect & PlanPrepare Site Cut-Out DimensionsCLRCO21 & CO11 Series CLR2160 Series CO29 SeriesProduct Dimensions Other Site Requirements Door Swing DimensionsDoor Reversability Door Alignment and AdjustmentReversing the door Standard DoorsPrepare door for reinstallation For black or white doors Install bottom hingeInstall top hinge, and door Prepare door for reinstallation175 mm Self-Closing DoorsReinstall hinge to top opposite Reinstall hinge to bottom oppositeReinstall Hole Plugs Install DoorPanel Dimensions Door Panel InstallationDoor Panel Installation Custom 1/4 Thick Door Panel InsertPrepare Power Supply Electrical SpecificationsCLR2160 & CLRCO2175 CO29 CO1175 CO2175FFP11 Prepare Plumbing Water Supply ConnectionDrain Connection CLR2160 CLRCO2175 Gravity DrainFactory-Installed Drain Pump Final Water Connection Locally-Installed Drain PumpInstall the Unit InstallationLeveling Information Level The UnitSolution Installation TroubleshootingInstallation Guide