U-Line CO2175, CO1175 manual Other Site Requirements, Door Swing Dimensions

Page 7

6 Door Swing Dimensions

All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 2” to accommodate the handle if the unit is installed next to a wall.

CO29

1/4" Min.

21-7/16"

Wall

CLR2160

Wall

1/4" Min.

 

2-1/8" Min.

90°

22-3/8"

21-3/4"

21-3/4"

16-1/2"

16-1/2"

90

90

Door Swing

Door Swing

Black and White

Stainless Steel

Wall

Wall

CLRCO2160

1/4" Min.

2-1/8" Min.

21-3/4"

21-3/4"

25-1/2"

25-1/2"

90

90

Door Swing

Door Swing

Black and White

Stainless Steel

Wall

Wall

CO1175

 

1/4" Min.

2" Min.

20-7/8"

20-7/8"

25-1/2"

25-1/4"

90

90

Door Swing

Door Swing

Black

Stainless

Wall

Wall

CO2175

 

1/4" Min.

2-1/8" Min.

21-7/16"

21-7/16"

25-1/2"

25-1/2"

90

90

Door Swing

Door Swing

Black and White

Stainless Steel

Door Swing

Other Site Requirements

Side-By-Side Installation

For a complete refreshment center, install two units side by side:

Cut-out width for a side-by-side installation is the total of the widths listed under Cut-Out Dimensions in each unit’s Installation Guide.

No trim kit is required. However, 1/4-inch space needs to be maintained between the units to ensure unobstructed door swing.

Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s Electrical Specifications Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications.

Water Supply

The unit requires a 1/4” O.D. soft copper supply line, or flexible water supply kit from U-Line (Part No. WATERHOOKUP).

Drain

The CLR2160 & CLRCO2175 require access to either a gravity or pump fed drain.

Environmental Requirements

The units are designed to operate between 50°F (10°C) and 100°F (37°C). High ambient temperatures (100°F [37°C] or higher) may reduce the unit’s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers.

If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the unit to prevent freezing damage, which is not covered by the warranty.

For best performance, keep the unit out of direct sunlight and away from heat generating equipment.

For best performance and life outdoors, place under a counter or provide shelter of some kind.

In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

Door Swing Dimensions

5

Image 7
Contents Install Guide Table of Contents General Precautions Safety Alert DefinitionsSafety Precautions Inspect & Plan Exterior Cleaning Product Registration Product Description Tools / Material RequiredCLR2160 Series CO29 Series Cut-Out DimensionsPrepare Site CLRCO21 & CO11 SeriesProduct Dimensions Other Site Requirements Door Swing DimensionsStandard Doors Door Alignment and AdjustmentDoor Reversability Reversing the doorPrepare door for reinstallation Install bottom hingePrepare door for reinstallation For black or white doors Install top hinge, and door175 mm Self-Closing DoorsInstall Door Reinstall hinge to bottom oppositeReinstall hinge to top opposite Reinstall Hole PlugsCustom 1/4 Thick Door Panel Insert Door Panel InstallationPanel Dimensions Door Panel InstallationCO29 CO1175 CO2175FF Electrical SpecificationsPrepare Power Supply CLR2160 & CLRCO2175Gravity Drain Water Supply ConnectionP11 Prepare Plumbing Drain Connection CLR2160 CLRCO2175Factory-Installed Drain Pump Final Water Connection Locally-Installed Drain PumpLevel The Unit InstallationInstall the Unit Leveling InformationSolution Installation TroubleshootingInstallation Guide
Related manuals
Manual 20 pages 22.86 Kb