4 Prepare Site
Your U-Line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear.
IMPORTANT
•Unit can NOT be installed behind a closed cabinet door.
•If you would like to align the face of the unit with other adjacent cabinet doors, you may need to alter the wall just behind the drain connection on the unit to accommodate the drain.
Cut-Out Dimensions
(CLR)CO21 & CO11 Series
See Electrical | |
Specifications | 24" |
for Power Supply |
34-1/4" | Minimum |
to | |
35-1/8" | |
8"
24-1/4"
Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
CLR2160 Series
CO29 Series
Filler Panel (Not Provided by U-Line) – May Be Added Above or Below Unit to Enclose for a Built-In Look
| Typical | See Electrical |
| Counter |
| Specifications |
| Height |
| for Power Supply |
| 34-1/4" |
| |
| to | 24" |
| 35-1/8" | Minimum |
| Cut-Out | |
| Height | |
| 28-5/8" | |
| to | |
| 28-7/8" | 8" |
| |
| | 21-1/16" |
Follow the cut-out drawing. The 21-1/16" width allows 1/4" for ease in installation and removal of the unit. 24" is the counter depth in most installations. The unit is 24" deep including the door and handle.
IMPORTANT
It is extremely important that this unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly.
| See Electrical | |
| Specifications | 24" |
| for Power Supply |
| |
34-1/4"
to
35-1/8"
8"
15-1/4"
Follow the cut-out drawing The 15-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.