Q: Problem

Water is leaking under the unit.

A: Solution

A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly.

Q: Problem

The door remains open unless it is pushed closed.

A: Solution

The hinges should be self-closing when the door is open approximately 8". If this is not the case, make sure the closers (at the bottom of the hinge pin) are clean, greased and installed correctly. Also, re-check leveling from front to back of the unit and readjust if necessary. Make sure that pivot plate is installed correctly.

Q: Problem

The custom overlay door was designed to align with the rest of the cabinet doors, but the unit has crept forward.

A: Solution

Make sure that the electrical cord and water supply line are not obstructing the installation.

Level & Install Unit

16

Image 18
Contents Install Guide Table of Contents Safety Alert Definitions General PrecautionsSafety Precautions Tools / Material Required Exterior CleaningProduct Registration Product Description Inspect & PlanCLRCO21 & CO11 Series Cut-Out DimensionsPrepare Site CLR2160 Series CO29 SeriesProduct Dimensions Door Swing Dimensions Other Site RequirementsReversing the door Door Alignment and AdjustmentDoor Reversability Standard DoorsInstall top hinge, and door Install bottom hingePrepare door for reinstallation For black or white doors Prepare door for reinstallationSelf-Closing Doors 175 mmReinstall Hole Plugs Reinstall hinge to bottom oppositeReinstall hinge to top opposite Install DoorDoor Panel Installation Door Panel InstallationPanel Dimensions Custom 1/4 Thick Door Panel InsertCLR2160 & CLRCO2175 Electrical SpecificationsPrepare Power Supply CO29 CO1175 CO2175FFDrain Connection CLR2160 CLRCO2175 Water Supply ConnectionP11 Prepare Plumbing Gravity DrainFactory-Installed Drain Pump Locally-Installed Drain Pump Final Water ConnectionLeveling Information InstallationInstall the Unit Level The UnitInstallation Troubleshooting SolutionInstallation Guide
Related manuals
Manual 20 pages 22.86 Kb