| Section 2 - Troubleshooting | |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cause |
| Remedy |
|
|
|
|
|
| |||
| Low ice production. |
|
|
| |||
| 1. | Control set too cold. | 1. | Adjust control warmer (counterclockwise). |
| ||
| 2. | Fan motor stalled. | 2. | Replace fan motor. |
| ||
| 3. | Ice cubes too large. | 3. | Lower water fill adjustment. |
| ||
| 4. | Dirty condenser. | 4. | Clean condenser. |
| ||
| 5. | Bypass valve stuck open (Frost Free units only). | 5. | Replace bypass valve (Frost Free units only). |
| ||
|
|
|
|
| |||
| Not freezing (compressor and fan motors |
|
|
| |||
| operating). |
|
|
| |||
| 1. | Little or no frost pattern on evaporator. | 1. | Check for sealed system leak or restriction. |
| ||
| 2. | Bypass valve stuck open (Frost Free units only). | 2. | Replace bypass valve (Frost Free units only). |
| ||
|
|
|
|
| |||
| Not freezing (compressor not operating - fans |
|
|
| |||
| operating). |
|
|
| |||
| 1. | Relay inoperable. | 1. | Replace relay. |
| ||
| 2. | Overload inoperable (open). | 2. | Replace overload. |
| ||
| 3. | Compressor inoperable. | 3. | Replace compressor. |
| ||
|
|
|
|
| |||
| Not freezing (compressor and fans not |
|
|
| |||
| operating). |
|
|
| |||
| 1. | Power cord not plugged in. | 1. | Plug in power cord. |
| ||
| 2. | On/Off switch in off position. | 2. | Turn switch to on position. |
| ||
| 3. | On/Off switch inoperable (open). | 3. | Replace On/Off switch. |
| ||
| 4. | Hold switch inoperable (open). | 4. | Replace hold switch. |
| ||
| 5. | Control inoperable | 5. | Replace control. |
| ||
| 6. | Broken wire in freeze circuit. | 6. | Repair or replace wiring. |
| ||
| 7. | Ejector blades not in freeze position (12:00) | 7. | Manually advance ejector blades to the 12:00 position (test ice maker and |
| ||
|
|
|
|
|
| limit switch). |
|
|
|
|
|
| |||
| Compressor overheating. |
|
|
| |||
| 1. | Condenser air flow restricted. | 1. | Remove restriction (clean condenser and grille). |
| ||
| 2. | Condenser fan blade obstructed. | 2. | Remove blade restriction. |
| ||
| 3. | Condenser fan motor stalled. | 3. | Replace fan motor. |
| ||
| 4. | Compressor inoperable. | 4. | Replace compressor. |
| ||
|
|
|
|
| |||
| Compressor will not stop operating. |
|
|
| |||
| 1. | Control set too cold. | 1. | Adjust control warmer (counterclockwise). |
| ||
| 2. | Control inoperable | 2. | Replace control. |
| ||
| 3. | Control sensing bulb not sensing mold temperature. | 3. | Fully insert bulb into ice maker tube. Rout bulb away from compressor |
| ||
| 4. | Evaporator fan stalled (Frost Free units only). |
| discharge tube. |
| ||
|
|
|
| ||||
|
|
|
|
| 4. | Remove obstruction or replace motor. |
|
|
|
|
|
|
|
|
|