Section 3 - Service and Repair
COMPRESSOR/ELECTRICAL SPECIFICATIONS
Compressor Pins
To measure start winding resistance, measure across the
To measure run winding resistance, measure across the
Models
EMI30HER Start winding resistance28 OHMS EMI30HER Run winding resistance8 OHMS
SD39 Start winding resistance11 OHMS SD39 Run winding resistance5 OHMS
EMI50HER Start winding resistance12 OHMS EMI50HER Run winding resistance4 OHMS
SD51 Start winding resistance5 OHMS
SD51 Run winding resistance5 OHMS115 Volt Ice maker heater resistance80 OHMS
115 Volt Water valve coil resistance335 OHMS
EMI ER
OVERLOAD PROTECTOR
|
| C |
STARTING RELAY | S | R |
|
|
RELAY COVER
Figure 4. Electrical Relay and Overload Protector
Models SP18, ULN-95, ULN-98, U-CO29A, U-CO1175, BI2115,ADA15IM, & SS-1095 MODEL U-CO29F - Figure 5
EMU45HSC Start winding resistance5.60 OHMS | 115 | Volt Ice maker heater resistance80 OHMS |
EMU45HSC Run winding resistance6.70 OHMS | 115 | Volt Water valve coil resistance335 OHMS |
| 115 | Volt Drain pan |
OVERLOAD PROTECTOR
STARTING RELAY
C
S R
RELAY COVER | CAPACITOR |