U-Line CLR2160 manual Drain Connection, Prepare Plumbing, Light Bulb Replacement, Gravity Drain

Page 19

Light Bulb Replacement

CLRCO2175

To replace the light bulb in your U-Line unit:

2

1

ULIN_0001_A

Figure 30

1.Grasp the edges of the light housing lens

(Figure 30, 1) opposite the exposed tab, and gently push the lens towards the tab (Figure 30, 2).

2.Pull the edge of the lens down (Figure 30, 1), and swing it out of the light housing.

IMPORTANT

ALWAYS use a genuine U-Line replacement bulb (P/N 31317) in the light housing. Use of any other bulb within the housing will generate excessive heat, causing damage to the light housing and cabinet interior, and compromising the precise temperature control of your unit.

3.Replace the bulb only with a genuine U-Line P/N 31317 replacement.

4.Replace the lens by first inserting the tab side back into the housing at a slight angle. While gently pushing the lens towards the tab end, push the free end up into the housing, and release when you will hear a snap/click.

7 Prepare Plumbing

CAUTION

Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.

Drain Connection

IMPORTANT

Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself.

The CLRCO2175 can be installed using a Gravity Drain, a Factory-Installed Drain Pump (U-Line P60) or a Locally- Installed (U-Line P60) Drain Pump. Drain lines must have a 5/8-inch inside diameter. The floor drain must be large enough to accommodate drainage from all attached drains.

Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor, causing water damage:

Gravity Drain

A Gravity Drain may be used if:

Drain line has at least a 1-inch drop per 48 inches of run (1/4 inch per foot).

Drain line does not create traps or created traps are vented (see Figure 31).

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

Figure 31

See Figure 32 for a typical Gravity Drain installation.

CLR2160, CLRCO2175

19

Image 19 Contents
CLR2160CLRCO2175 Use and Care GuidePlease Record Your Model Information Warranty RegistrationIntroduction Table of Contents This page intentionally left blank CLR2160, CLRCO2175 General Precautions Safety Alert DefinitionsSafety Precautions Exclusive Features of Échelon Product FeaturesCLR2160 Other Site Requirements Initial StartupOperation Interior Lighting Temperature ControlChecking Product Temperature Temperature Display SelectionOutdoor Usage Temperature DisplayAdjusting Temperature Normal Operating SoundsProduct Disposal Storage, Vacation, MovingMaintenance General CleaningCleaning and Maintenance Clear Ice Maker Maintenance Condenser CleaningRemove inside front cover Leveling Ice Cube Thickness Adjustment Interval As Required 175 mm Door Alignment Check and AdjustmentDoor Reversal ULIN0002A Door Shelf Removal/Insertion Glass Shelf Removal/InstallationGravity Drain Light Bulb ReplacementDrain Connection Prepare PlumbingFactory-Installed Drain Pump Locally-Installed Drain Pump Water Supply Connection Replacement Parts Electrical SpecificationsBefore Calling for Service If Service is RequiredElectrocution Hazard Troubleshooting GuideMaintenance ICE Maker Self Cleaning Cycle All Models Task Touch Display Comment Electronic Control Quick GuideLine Corporation Limited Warranty For General Inquiries For Service and Parts Assistance
Related manuals
Manual 180 pages 38.87 Kb