6 FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “5.1 Removing the control panel / 5.2 Removing the hob”.

6.1Adjustment of minimum for natural gas

Light the burner and take it to the minimum . Remove the gas tap knob and turn the adjustment screw at the side of the tap shaft until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

16

Image 14
Contents Contents Declines ALL Responsibility for Improper USE IntroductionInstructions for Safe and Proper USE Never Unplug by Pulling on the CablePlate on the Casing Must not be Removed Attachment to the support structure Instructions for the installerPositioning of the HOB Fixing 90 cm hobs on 60 cm base unit Clearance above and around domestic appliances Requirements Room ventilation Discharge of combustion products GAS Connection Electrical Connection Adaptation to Different Types of GAS Adjustment for Ulpg Removing the hob models with built-in control PanelAdjustment for natural gas Adjustment of minimum for natural gas Final OperationsCm hobs BurnersLubrication of gas taps Instructions for the user Using the HOBPractical advice for using the burners Ignition of the burnersElectric elements Using the electric elementsDiameter of containers Turning on electric elementsTo use correctly remember to Cleaning of cooking hob components Cleaning and MaintenanceCleaning Cover Preventive maintenanceElectric element Cause Problems and CausesProblem What to doPage 914773237/ B