Smeg CIR34AX3 manual GAS Connection

Page 9

Instructions for the installer

3 GAS CONNECTION

This appliance is suitable for installation with Natural Gas or ULPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of ULPG (propane) appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

1.annealed copper pipe or;

2.flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm diameter.trewqertttt

The appliance must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the appliance is operated make certain all relevant parts are placed in the correct position.

When the installation is completed the installation connections of appliance will require to be leak tested, the burner operating pressure and flame checked and adjusted.

Warranty service calls do not cover these adjustments!

To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed.

N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0kPa after installation.

U.L.P.G. Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2.75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2.75kPa.

11

Image 9
Contents Contents Instructions for Safe and Proper USE IntroductionDeclines ALL Responsibility for Improper USE Never Unplug by Pulling on the CablePlate on the Casing Must not be Removed Instructions for the installer Positioning of the HOBAttachment to the support structure Fixing 90 cm hobs on 60 cm base unit Clearance above and around domestic appliances Requirements Room ventilation Discharge of combustion products GAS Connection Electrical Connection Adaptation to Different Types of GAS Removing the hob models with built-in control Panel Adjustment for UlpgAdjustment for natural gas Final Operations Adjustment of minimum for natural gasBurners Cm hobsLubrication of gas taps Practical advice for using the burners Using the HOBInstructions for the user Ignition of the burnersDiameter of containers Using the electric elementsElectric elements Turning on electric elementsTo use correctly remember to Cleaning and Maintenance CleaningCleaning of cooking hob components Preventive maintenance Electric elementCover Problem Problems and CausesCause What to doPage 914773237/ B