Smeg SA9058X manual Gas connection

Page 6

Instructions for the installer

3.2 Gas connection

This appliance is suitable for installation with Natural Gas or ULPG (propane). Refer to page 13 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of LPG (propane) appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

1.annealed copper pipe or;

2.Flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm diameter, max length 100 mm.

The cooker must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the cooker is operated make certain all relevant parts are placed in the correct position.

When the installation is completed the installation connections of cooker will require to be leak tested, the burner operating pressure and flame checked and adjusted.

Warranty service calls do not cover these adjustments!

To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed.

N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0kPa after installation.

U.L.P.G. Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2.75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2.75kPa.

8

Image 6
Contents Contents Never Attempt to Repair the Appliance Yourself Instructions Safety and USEIntroduction Do not Remove this Plate for ANY ReasonIntroduction Instructions for disposal Instructions for Disposal OUR Enviromental CareInstructions for the installer Installation of the ApplianceElectrical connection Gas connection Room ventilation Discharge of combustion productsClearance above and around domestic cookers RequirementsAdaptation to Different GAS Types Replacing the hob injectorsBurner Burner and nozzle characteristics tableBurner arrangement on the hob Nominal gas Turn-down gas Injector Consumption MJ/hFinal Procedures Regulation of the hob burner minimum level for UlpgWall fixing HOB Burner Control Knob User InstructionsDescription of Controls on the Front Panel Electric Oven Thermostat KnobMultifunction Electric Oven Function Knob Lighting the hob burners Using the HOBPractical advice for the use of the hob burners Cookware diameter 90 cm modelUsing the electric grill Using the OvenGeneral warnings and advice Using the grill in cooking rangesUsing the grill Storage compartmentFood Runner Level Automatic cooking Time settingSemi-automatic cooking List of FunctionsEnd of cooking TimerAdjusting the buzzer volume Silencing the buzzerAvailable Accessories Accessories available on requestCleaning and Maintenance Cleaning stainless steelCleaning the hob components Cleaning the inside of the oven Door glassLighters and thermocouples Replacing the bulb Extraordinary MaintenanceLubricating the taps and gas oven thermostat Demounting the doorPage 914779058/ a