Smeg ALFA41VEK manual Levelling, Connection to the water supply, Steam vent pipe

Page 5

Instructions for the Installer

2.2Levelling

Level the oven by means of its four adjustable feet. To make the adjustment, undo the lock-nut and unscrew the foot. The adjuster screw travel is 10 mm.

2.3Connection to the water supply

Connect the water inlet connection on the rear to a water supply outlet having ¾ gas threaded connection, taking care to screw tightly to the hose.

If the water supply pipe is new or has been unused for a long time, before making the connection turn the water on and allow it to flow out to ensure that it is clear and free from impurities. Otherwise, the water inlet may become fouled, damaging the oven.

The oven must be supplied with water at a pressure between min. 50 kPa and max. 500 kPa.

2.4Steam vent pipe

The rear of the oven is fitted with a pipe which vents the steam produced during cooking. This pipe must be left free of all obstructions. Take care not to crush it.

25

Image 5
Contents Table of Contents Introduction Precautions for Safety and USEIntroduction Electrical connection Instructions for the InstallerInstalling the Oven Steam vent pipe LevellingConnection to the water supply Description of Front Panel Controls Instructions for the UserSetting the time Using the OvenPrecautions and General Advice Program selection Presettings ProgramsInstructions for the User Editing a program Humidified fan-mode cookingProgrammed preheating P9 Setting programmed preheatingModifying a previously edited program How programmed preheating works Manual mode cookingTechnical notes How to use this programCleaning stainless steel Cleaning and MaintenanceDoor glazing Cleaning the inside of the ovenChanging the light bulb Extraordinary MaintenanceOven door gasket Removing the door