Instructions for the installer
When linking up to mains by plug and socket, the connection must be completed with a
If the appliance is connected to the electrical mains supply in a permanent manner, install a multipolar
WARNING: if the phase voltage drops below 190 VAC, the performance of the oven may suffer, not due to the product itself.
The terminal marked with this symbol connects parts together that are normally at zero potential. Connect the appliances appropriately using this terminal in order to make sure that they are equipotential.
2.1.1 Safety thermostat
The oven is equipped with a safety device that takes action in case of serious malfunction. To
The manufacturer declines all responsibility for damage to persons or things caused by the
2.2Levelling
Level the oven on the ground using the four adjustable feet. In order to adjust them, loosen the lock nut and unscrew the foot. The adjustment screws have a range of 10 mm.
25